Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Autocad related pdf t help the student for future, Papers of Civil Engineering

A detailed plan for the construction of a fuel station. It includes information on the layout of the station, the materials to be used, and safety precautions. The plan also includes details on the tanks, pumps, and other equipment to be installed. intended for use by engineers and contractors involved in the construction of the fuel station.

Typology: Papers

2021/2022

Available from 01/05/2023

vishal025
vishal025 🇮🇳

1 document

1 / 1

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
BUILDING PLAN
TOPO PLAN
NOT TO SCALE
0.25
0.15 1.20
.23M
0.25
G.L. G.L.
Plinth beam
9"x12"
P.C.C. 1:5:10
COLUMN ROD
BOTH WAYS
4 Nos 12 Ø
COLUMN MATT
SAND FILLING
CANOPY SECTION
3.50
PUMP
3.50
1.0M
CANOPY SECTION
WBM IN TWO LAYER 75mm TH.
BITUMINOUS MACADAM
( NP4 CLASS )
FILLING
GL
.10
.10 SECTION
R.C.C1:2:4 0.23TH.
GL
SAND FILLING 0.3TH.
C.C1:4:8 0.23TH. PLAN
HUME PIPE CULVERT
PREMIX CARPET 20mm TH.
75 mm TH.
900MMØ R.C. HUME PIPE
WELL GRADED GRAVEL
1.00M @0.12M C/C
10mm RTS
12mm RTS
@0.12M C/C
NOTE :
1. PROPOSAL SHOWN IN RED.
2. DISMANTLED SHOWN IN YELLOW
3. APPROVED BUT NOT CONSTRUCTED SHOWN IN GREEN
4. PRO. TANK IS CONFG TO IS 10987.
5. END PLATE 8MM TH, SHELL PLATE 6MM TH.
6. FILL POINT 3.60M SAFETY RADIUS (FILLING POINT IN TANK TOP FILL
PIPE)
7 1.20M HT. COMPOUND WALL.
8. NO ELECTRICAL WIRE PASSING OVER THE SITE.
9. VENT PIPE 40MMØ 6.0M HT AND 4.5M CLEARANCE COVERED WITH
TWO LAYERS OF NON-CORRODING METAL WIRE MESH 11 PER LINEAR
CM. 10. 12NOS. FIRE EXTINGUISHERS D.C.P. TYPE, 10KGS.CAP.AND
12NOS. SAND BUCKETS PROVIDED.
11. HSD/MS DISPENSING PUMP CONFG. TO IS 2148. FILL PIPE AND DIP
PIPE OF UNDER GROUND TANKS
12. ARE PROVIDED WITH AIR TIGHT THREADED BRASS CAP.
TANK DETAILS
CERTIFIED THAT
B. ALL FACILITIES WILL BE INSTALLED EXACTLY AS PER
A.NECESSARY APPROVALS/CLEARANCES FROM MOP,
,IRC AND ALL OTHER CONCERNED ,
THIS PLAN
CAPACITY PRODUCT PUMP
2X20 KL HSD
TANK SIZE
MPD PUMP 2.10MØX6.25
PLATE THICKNESS
END
8MM
SHELL
5MM
6MM
PLOT DETAILS:
COMPOUND WALL DETAIL
GL
COMPOUND WALL
1.20MHT. ALROUND
GL
P.C.C (1:3:6)
R.R IN CM 1:6
S.NO.
VILLAGE
TALUK
DISTRICT
STATE
PIN
IndianOil
INDIANOIL CORPORATION LTD
MARKETING DIVISION
TRICHY DIVISIONAL OFFICE
B34,3RD FLOOR ,THIRIVENI BUILDING
SASTRI ROAD THILAI NAGAR
TRICHY-18.
NEAREST POLICE STATION
NEAREST RAILWAY STATION
NEAREST FIRE STATION
-
-
-
-
-
-
-
-
-
.10 .90M .75M
0.15
1.37
1.5M 1.50M
S
N
V
F
G
P
LEGENDS:-
CNG PIPE LINE. ARROW IN DIRECTION OF FLOW.
SAND BUCKET
"NO SMOKING" SIGN
"STOP VEHICLE" SIGN
"NO OPEN FLAME PERMITTED" SIGN
"FLAMMABLE GAS" SIGN
SIGN SHOWING DETAILED PRECAUTIONS
& PROCEDURE OF REFUELLING.
DCP(10) DCP ( 10 kg )
DCP(75) DCP ( 75 kg )
EEARTH PIT
EE INSTRUMENT EARTH PIT
1 NO.
3 NOS.
3 NOS.
3 NOS.
3 NOS.
3 NOS.
5 NOS.
1 NO.
4 NOS.
1 NO.
C. THIS IS NOT A RE-SITE MENT CASE
D. NO CASE IS PENDING IN ANY COURT OF LAW AGAINST THIS
PERMISES/DEALERSHIP
E. ERACTION OF CANOPY IS AS PER IS STANDARD DRAWINGS
APPROVED BY CCOE/NAGPUR,VIDE REF.NO.P6(5)83 DATED 09.05.2003
DRSH
INDIAN OIL CORPORATION LTD,
TIRCHY DIVISIONAL OFFICE
B-35,3RD FLOOR,TRIVENI BUILDING,
SASTRI ROAD,THILLAI NAGAR,
TIRCHY-18.
PREPARED. MS REFLECTIVE TECHNO STYLE.
CHKD.BY- MGR (E) CH.MGR(E) CH.MGR(RS) DRAWING NO.-
APPROVED BY- DRH
DATE ;- 26.12.2022
APPLYING FOR NOC.&EXPLOSIVE
BRIEF RECORDS
DATE. REVISED
26.12.2022
B R I E F R E C O R D S SIGN.
AREA OF THE RO = 1026.59SQ.M
AREA OF THE SALES BUILFING = 54.15 SQ.M
AREA OF THE CANOPY = 78.00 SQ.MT
E
W
S
N
FOUNDATION DETAIL
LIC NO. P/SC/TN/14/5364(P226156)
M/S R.R.R AGENCIES
620/3,620/4 & 620/5
THIRUBUVANAM
TAMILNADU
TCHDO/RO/2007(REV.)
THIRUVEDAIMARUDHUR
THANJAVUR
5.19M
6.39M
31.60M
28.40M
22.50M
10.40M
9.00M
13.34M
BUFFER STRIP
6.00MX1.50M
ENTRY
EXIT
7.07M
13.21M
12.89M DUO
HSD/MS
HSD
9.00M
13.58M
11.27M
MS MS
6.00M
D F
SS
S
V
M
20KL
HSD
3.60M
D F
SS
S
V
M
15KL
MS
3.60M
D F
SS
S
V
M
20KL
HSD
1.8M
1.5M
V M
D F
SS
S
10KL MS
3.60M
4.00M
35.80M
BRICK MASONARY
COMPOUND WALL
1.20M HIGH
VENT PIPE 40MM&4.50M
HIGH FROM G.L
2X20KL H.S.D. TANK
2.10MX6.25M LONG IN
MESONARY PIT WITH MAT
RAFT AND TOPCOVERED BY
R.C.C SLAB.
1X15KL M.S. TANK
1.95MX5.50M LONG IN
MESONARY PIT WITH MAT
RAFT AND TOP
COVERED BY R.C.C SLAB.
1X10KL H.S.D. TANK
1.95MX3.75M LONG IN EARTH
PIT WITH MAT RAFT AND TOP
COVERED BY SAND.
1X20KL H.S.D. TANK
2.10MX6.25M LONG IN EARTH
PIT WITH MAT RAFT AND TOP
COVERED BY SAND.
DRY SAND
BUCKETS
2 NOS. PUMP ISLAND 5.54MX1.0M
E/O MPD,HSD/MS DISPENSING
PUMP CONFG. TO IS 2148 , 8 NOS.
SAND BUCKETS AND F.E
7.00M
6.71M
P.W.D BOUNDARY LINE
P.W.D BOUNDARY LINE
ROAD APPRAOACH
ROAD APPRAOACH
C/L OF ASPHALTED ROAD
S.H. ROAD
TO KUMBHAKONAM 6.7KM.
TO MAYILADUTHURAI
28.5KM.
MILESTONE
KUMBAKONAM 6.8KM.
2230
2.00M
1.50M
3.80M
ELECTRIC ROOM
4.60X3.40
DEALERS
ROOM
2.80X3.40
URINAL
STORE
1.50X1.92
G.TOILET
1.8X1.2
G.TOILET
1.8X1.2
D
D
D
D
FE
FE
D.P SWITCH
EXHAUST PIPE
WITH SPARK ARRESTOR
6.54M
VENT PIPE 40MM&4.50M
HIGH FROM G.L
KIOSK
3.98X2.30 D
1.57M
6.77M
HIGH MAST
HOARDING BOARD
Y/L
Y/L
Y/L
Y/L
MAIN SIGN POLE
METRE BOX
HOARDING BOARD
THANK YOU SIGN
12.50M
18.00M
STRUCTRUAL
CANOPY18.00MX12.50M
DUO
HSD/MS
HSD
9.00M
MS
12.50M
18.00M
3.50M
3.50M
3.50M
3.50M
3.50M
3.50M
ELECTRIC
ROOM
4.60X3.40
DEALERS
ROOM
2.80X3.40
URINAL
STORE
1.50X1.92
G.TOILET
1.8X1.2
G.TOILET
1.8X1.2
D
D
D
D
FE
FE
R=100.00M
R=100.00M
R=100.00M
R=100.00M
IOCL RO
SITE
5.19M
6.39M
31.60M
28.40M
22.50M
35.80M
7.00M
6.71M
P.W.D BOUNDARY LINE
P.W.D BOUNDARY LINE
ROAD APPRAOACH
ROAD APPRAOACH
C/L OF ASPHALTED ROAD
S.H. ROAD
TO KUMBHAKONAM 6.7KM.
TO MAYILADUTHURAI 28.5KM.
S.H. ROAD
RESIDENCY
RESIDENCY
RESIDENCY
RESIDENCY
RESIDENCY
RESIDENCY
RESIDENCY RESIDENCY RESIDENCY
AGRI OFFICE
VACANT LAND
VACANT LAND
VACANT LAND
AREA OF THE ROAD MARGIN = 190.50SQ.M
THIRUVEDAIMARUDHUR
THIRUVEDAIMARUDHUR
THIRUVEDAIMARUDHUR
PLAN SHOWING THE PRO HSD/MS SERVICE STATION,KUMBAKONAM TO MYLADUTHURAI ROAD
1X10 KL MS/XP 2NOS HSD 1.95MØX3.75 5MM 6MM
.60M
2.11M
.30M
.0.60M 6.25M .60M
LONGITUDINAL SECTION OF 20KL U/G TANK
0.60m
2.11m
.30M
SCALE : 1:200

Partial preview of the text

Download Autocad related pdf t help the student for future and more Papers Civil Engineering in PDF only on Docsity!

BUILDING PLAN

TOPO PLAN

NOT TO SCALE

0.15 (^) 1. .23M

G.L. G.L.

Plinth beam

9"x12"

P.C.C. 1:5:

COLUMN ROD

BOTH WAYS

4 Nos 12 Ø

COLUMN MATT

SAND FILLING

CANOPY SECTION

PUMP

1.0M

CANOPY SECTION

WBM IN TWO LAYER 75mm TH.

BITUMINOUS MACADAM

( NP4 CLASS )

FILLING

GL

. .10 (^) SECTION

R.C.C1:2:4 0.23TH.

GL

SAND FILLING 0.3TH.

C.C1:4:8 0.23TH.

PLAN HUME PIPE CULVERT

PREMIX CARPET 20mm TH.

75 mm TH.

900MMØ R.C. HUME PIPE

WELL GRADED GRAVEL

1.00M

@0.12M C/C

10mm RTS

12mm RTS

@0.12M C/C

NOTE :

  1. PROPOSAL SHOWN IN RED.
    1. DISMANTLED SHOWN IN YELLOW
    2. APPROVED BUT NOT CONSTRUCTED SHOWN IN GREEN
      1. PRO. TANK IS CONFG TO IS 10987.
    3. END PLATE 8MM TH, SHELL PLATE 6MM TH.
    4. FILL POINT 3.60M SAFETY RADIUS (FILLING POINT IN TANK TOP FILL PIPE) 7 1.20M HT. COMPOUND WALL.
      1. NO ELECTRICAL WIRE PASSING OVER THE SITE.
      2. VENT PIPE 40MMØ 6.0M HT AND 4.5M CLEARANCE COVERED WITH TWO LAYERS OF NON-CORRODING METAL WIRE MESH 11 PER LINEAR CM. 10. 12NOS. FIRE EXTINGUISHERS D.C.P. TYPE, 10KGS.CAP.AND 12NOS. SAND BUCKETS PROVIDED.
  2. HSD/MS DISPENSING PUMP CONFG. TO IS 2148. FILL PIPE AND DIP PIPE OF UNDER GROUND TANKS
  3. ARE PROVIDED WITH AIR TIGHT THREADED BRASS CAP.

TANK DETAILS

CERTIFIED THAT

B. ALL FACILITIES WILL BE INSTALLED EXACTLY AS PER

A.NECESSARY APPROVALS/CLEARANCES FROM MOP, ,IRC AND ALL OTHER CONCERNED ,

THIS PLAN

CAPACITY PRODUCT PUMP

2X20 KL HSD

TANK SIZE

MPD PUMP 2.10MØX6.

PLATE THICKNESS END

8MM

SHELL 5MM 6MM

PLOT DETAILS:

COMPOUND WALL DETAIL

GL

COMPOUND WALL

1.20MHT. ALROUND

GL

P.C.C (1:3:6)

R.R IN CM 1:

S.NO.

VILLAGE

TALUK

DISTRICT

STATE

PIN

IndianOil

INDIANOIL CORPORATION LTD

MARKETING DIVISION

TRICHY DIVISIONAL OFFICE B34,3RD FLOOR ,THIRIVENI BUILDING SASTRI ROAD THILAI NAGAR TRICHY-18.

NEAREST POLICE STATION

NEAREST RAILWAY STATION

NEAREST FIRE STATION


.10 .90M

.75M

1.5M

1.50M

S N V F G P

LEGENDS:- CNG PIPE LINE. ARROW IN DIRECTION OF FLOW. SAND BUCKET "NO SMOKING" SIGN "STOP VEHICLE" SIGN "NO OPEN FLAME PERMITTED" SIGN "FLAMMABLE GAS" SIGN SIGN SHOWING DETAILED PRECAUTIONS & PROCEDURE OF REFUELLING. DCP(10) DCP ( 10 kg ) DCP(75) DCP ( 75 kg ) E EARTH PIT EE (^) INSTRUMENT EARTH PIT

1 NO.

3 NOS.

3 NOS.

3 NOS.

3 NOS.

3 NOS.

5 NOS.

1 NO.

4 NOS.

1 NO.

C. THIS IS NOT A RE-SITE MENT CASE

D. NO CASE IS PENDING IN ANY COURT OF LAW AGAINST THIS PERMISES/DEALERSHIP E. ERACTION OF CANOPY IS AS PER IS STANDARD DRAWINGS APPROVED BY CCOE/NAGPUR,VIDE REF.NO.P6(5)83 DATED 09.05.

DRSH

INDIAN OIL CORPORATION LTD,

TIRCHY DIVISIONAL OFFICE

B-35,3RD FLOOR,TRIVENI BUILDING,

SASTRI ROAD,THILLAI NAGAR,

TIRCHY-18.

PREPARED. MS REFLECTIVE TECHNO STYLE.

CHKD.BY- MGR (E) CH.MGR(E)^ CH.MGR(RS)^

DRAWING NO.-

APPROVED BY- DRH

DATE ;- 26.12.

APPLYING FOR NOC.&EXPLOSIVE

BRIEF RECORDS

DATE. REVISED

B R I E F R E C O R D S SIGN.

AREA OF THE RO = 1026.59SQ.M AREA OF THE SALES BUILFING = 54.15 SQ.M AREA OF THE CANOPY = 78.00 SQ.MT

W E

S

N

FOUNDATION DETAIL

LIC NO. P/SC/TN/14/5364(P226156)

M/S R.R.R AGENCIES

THIRUBUVANAM

TAMILNADU

TCHDO/RO/2007(REV.)

THIRUVEDAIMARUDHUR

THANJAVUR

5.19M

6.39M

31.60M

28.40M

22.50M9.00M 10.40M

13.34M

BUFFER STRIP

6.00MX1.50M

ENTRY EXIT

7.07M

12.89M 13.21M DUO HSD/MS

HSD

9.00M

11.27M 13.58M MS (^) MS

6.00M

D FS

S S

V M 20KL 3.60MHSD

D FS

S S

V M 15KL 3.60MMS

D FS

S S

V M 20KL HSD

1.5M 1.8M

V M S^ D F S

S

10KL MS

3.60M

4.00M

35.80M

BRICK MASONARY

COMPOUND WALL

1.20M HIGH

VENT PIPE 40MM&4.50M

HIGH FROM G.L

2X20KL H.S.D. TANK

2.10MX6.25M LONG IN

MESONARY PIT WITH MAT

RAFT AND TOPCOVERED BY

R.C.C SLAB.

1X15KL M.S. TANK

1.95MX5.50M LONG IN

MESONARY PIT WITH MAT

RAFT AND TOP

COVERED BY R.C.C SLAB.

1X10KL H.S.D. TANK

1.95MX3.75M LONG IN EARTH

PIT WITH MAT RAFT AND TOP

COVERED BY SAND.

1X20KL H.S.D. TANK

2.10MX6.25M LONG IN EARTH

PIT WITH MAT RAFT AND TOP

COVERED BY SAND.

DRY SAND

BUCKETS

2 NOS. PUMP ISLAND 5.54MX1.0M

E/O MPD,HSD/MS DISPENSING

PUMP CONFG. TO IS 2148 , 8 NOS.

SAND BUCKETS AND F.E

7.00M

6.71M

P.W.D BOUNDARY LINE

P.W.D BOUNDARY LINE

ROAD APPRAOACH

ROAD APPRAOACH

C/L OF ASPHALTED ROAD

S.H. ROAD

TO KUMBHAKONAM 6.7KM.

TO MAYILADUTHURAI

28.5KM.

MILESTONE

KUMBAKONAM 6.8KM.

2230

2.00M

1.50M

3.80M

ELECTRIC ROOM 4.60X3.

DEALERS ROOM 2.80X3.

URINAL

STORE1.50X1.

G.TOILET1.8X1.

DG.TOILET1.8X1.

D

D

D

FE

FE

D.P SWITCH

EXHAUST PIPE

WITH SPARK ARRESTOR

6.54M

VENT PIPE 40MM&4.50M

HIGH FROM G.L

KIOSK

3.98X2.30 D

1.57M

6.77M

HIGH MAST

HOARDING BOARD

Y/L

Y/L

Y/L

Y/L

MAIN SIGN POLE

METRE BOX

HOARDING BOARD

THANK YOU SIGN

12.50M

18.00M

STRUCTRUAL

CANOPY18.00MX12.50M

DUO

HSD/MS

HSD

9.00M

MS

12.50M

18.00M

3.50M

3.50M

3.50M

3.50M

3.50M 3.50M

ELECTRIC

ROOM

4.60X3.

DEALERS

ROOM

2.80X3.

URINAL

STORE 1.50X1.

G.TOILET 1.8X1.

G.TOILET 1.8X1.

D

D

D

D

FE

FE

R=100.00M

R=100.00M

R=100.00M R=100.00M

IOCL RO

SITE

5.19M

6.39M

31.60M

28.40M

22.50M

35.80M

7.00M

6.71M

P.W.D BOUNDARY LINE P.W.D BOUNDARY LINE ROAD APPRAOACH

ROAD APPRAOACH

C/L OF ASPHALTED ROADS.H. ROAD TO KUMBHAKONAM 6.7KM.

TO MAYILADUTHURAI 28.5KM. S.H. ROAD

RESIDENCY

RESIDENCY

RESIDENCY

RESIDENCY

RESIDENCY

RESIDENCY

RESIDENCY RESIDENCY RESIDENCY

AGRI OFFICE

VACANT LAND

VACANT LAND

VACANT LAND

AREA OF THE ROAD MARGIN = 190.50SQ.M

THIRUVEDAIMARUDHUR

THIRUVEDAIMARUDHUR

THIRUVEDAIMARUDHUR

PLAN SHOWING THE PRO HSD/MS SERVICE STATION,KUMBAKONAM TO MYLADUTHURAI ROAD

1X10 KL MS/XP 2NOS HSD 1.95MØX3.75 5MM^ 6MM

.60M

2.11M

.30M .0.60M 6.25M .60M

LONGITUDINAL SECTION OF 20KL U/G TANK

0.60m

2.11m

.30M

SCALE : 1: