A collection of multiple-choice questions and answers related to the bicsi installer 1 exam. It covers various topics relevant to telecommunications infrastructure, including cabling, firestopping, grounding, and testing. The document can be a valuable resource for individuals preparing for the bicsi installer 1 certification exam.

Typology: Exams

2024/2025

Available from 03/27/2025

Andreas-best
Andreas-best 🇬🇧

726 documents

1 / 31

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1
BICSI - INSTALLER 1
EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS
(100% CORRECT ANSWERS)
"C - CORRECT ANSWER Which of the following is a property of an electromagnetic field built
around a conductor that opposes any changes in current flow in a circuit?
A Impedance
B Capacitance
C Inductance
D Resistance"
"A - CORRECT ANSWER Which of the following markings is used for non-conductive optical
fiber general-purpose cables?
A OFNG
B OFCR
C OFCP
D OFNP"
"B - CORRECT ANSWER What is the specified performance level for Category 6 cable?
A 100 MHz
B 250 MHz
C 500 MHz
D 600 MHz"
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f

Partial preview of the text

Download BICSI Installer 1 Exam Questions and Answers and more Exams Information and Communications Technology (ICT) in PDF only on Docsity!

BICSI - INSTALLER 1

EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS

(100% CORRECT ANSWERS)

"C - CORRECT ANSWER Which of the following is a property of an electromagnetic field built

around a conductor that opposes any changes in current flow in a circuit? A Impedance B Capacitance C Inductance D Resistance"

"A - CORRECT ANSWER Which of the following markings is used for non-conductive optical

fiber general-purpose cables? A OFNG B OFCR C OFCP D OFNP"

"B - CORRECT ANSWER What is the specified performance level for Category 6 cable?

A 100 MHz B 250 MHz C 500 MHz D 600 MHz"

"D - CORRECT ANSWER Which of the following is the primary benefit of using wall-mounted

racks and cabinets in place of traditional equipment racks? A Provides equipment with a higher level of protection B Allows for the equipment to be easily rearranged C Optimizes airflow within the equipment room D Takes up less space within the equipment room"

"B - CORRECT ANSWER Which of the following is designed to provide protection from harmful

chemicals? A Cut-resistant gloves B Rubber gloves C Leather gloves"

"B - CORRECT ANSWER Which of the following is a building-serving space that houses large

pieces of common active equipment? A TR B ER C TE D Mechanical Room E Battery room"

"C - CORRECT ANSWER Which phase of testing includes documenting the test results?

A Phase 1 B Phase 2

A Choice of words B Body language C Tone of voice"

"C - CORRECT ANSWER Which of the following attachment methods does BICSI recommend

for attaching coaxial connectors to coaxial cable? A Screw-on B Push-on C Compression D Crimp"

"D - CORRECT ANSWER Electrical power (P) is measured in ___________?

A Ohms B Farads C henries D Watts"

"D - CORRECT ANSWER What is the maximum allowable horizontal cable length?

A 10 m (33 ') B 30 m (100') C 50 m (164') D 90 m (295')"

"C - CORRECT ANSWER Which of the following describes a nonmechanical firestop system

that forms a hard char when exposed to flame?

A Elastomeric B Intumescent C Ablative D Endothermic"

"B - CORRECT ANSWER How much cable slack should be left in the work area after

termination? A 0.5m (1.6') B 1m (3.3') C 1.2 m (4') D 3m (10')"

"D - CORRECT ANSWER Which of the following types of cable produces very little smoke when

burned? A CM B CMG C CMUC D LSZH"

"B - CORRECT ANSWER How much sheath of the cable needs to be removed in order to

properly terminate an 8P8C? A 6.3mm (0.25") B 12.7mm (0.5") C 25mm (1")

B Qualification tester C Telephone test set D TDR"

"C - CORRECT ANSWER Which of the following markings indicates that the cable is designed

for use in a plenum space? A CMR B CMUC C CMP D CMX"

"D - CORRECT ANSWER Which of the following is used to express system gain and loss?

A Ohms B Henries C Farads D Decibel (dB)"

"A - CORRECT ANSWER Which type of cabling is installed between a main cross-connect

(campus distributor) and an intermediate cross-connect (building distributor)? A First-level backbone B Second-level backbone C Horizontal"

"B - CORRECT ANSWER Which of the following steps should be performed first when an

installer is pulling backbone cable from the bottom up?

A Label cables and reels B Verify the proper cable run C Determine appropriate rope size D Move cable reels into place"

"B - CORRECT ANSWER A third 90-degree bend may be permitted in a conduit run if the run

does NOT exceed ______? A 5 m (16.5') B 10 m (33') C 15 m (50') D 30 m (100')"

"B - CORRECT ANSWER What is the most appropriate administration class for an

infrastructure with multiple telecommunications spaces within one building? A Class 1 B Class 2 C Class 3 D Class 4"

"C - CORRECT ANSWER Which of the following must be measured before the length of a

coaxial cable can be calculated? A Propagation delay B Insertion loss C DC loop resistance

B BBC

C RBB

D TEBC"

"C - CORRECT ANSWER How many cycles are in 10Hz?

A 1

B 5

C 10

D 20"

"C - CORRECT ANSWER Which of the following is used to connect cabinets to the nearest SBB?

A RBB

B TBB

C TEBC

D BBC"

"C - CORRECT ANSWER What method of transmission is used to transmit signals during a

telephone call? A Simplex B Half-duplex C Full duplex"

"C - CORRECT ANSWER You are terminating a category 3 cable. What is the maximum

permissible amount of untwisting? A 25 mm (1")

B 38 mm (1.5") C 75 mm (3") D 100 mm (4")"

"A - CORRECT ANSWER Which of the following fire-ratings provides information about smoke

leakage? A L rating B I rating C E rating D W rating"

"A - CORRECT ANSWER What is the minimum number of consolidation points that should

serve an open office furniture cluster? A 1 B 2 C 3 D 4"

"A - CORRECT ANSWER What is the bend radius requirement for optical fiber cable when the

cable is at rest? A 10 times the cables outside diameter B 15 times the cables outside diameter C 20 times the cables outside diameter"

"A - CORRECT ANSWER A grey backboard should be used to identify _____ backbone cable?

A 25 mm (1") B 38 mm (1.5") C 45 mm (1.75") D 50 mm (2")"

"B - CORRECT ANSWER Which type of cabling is installed between a main cross connect and a

horizontal cross connect? A Second-level backbone B First-level backbone C Horizontal"

"A - CORRECT ANSWER If the situation requires, a conduit should be terminated _______ the

plywood backboard? A Through B Above C Below"

"A - CORRECT ANSWER Which of the following combinations is used to identify the tip

conductors in Pair 1 of a 4-pair cable? A White-Blue B White-Orange C Green-White D Brown-White"

"B - CORRECT ANSWER What type of coaxial cable is used for video backbone distribution?

A Series 6 B Series 11 C RG 59 D RG 58"

"A - CORRECT ANSWER A third 90-degree bend may be permitted in a conduit run if one of the

bends is located within ____ of the cable feed end? A 300 mm (12") B 375 mm (15") C 450 mm (18") D 483mm (19")"

"D - CORRECT ANSWER Which pair of a 100-ohm balanced twisted pair patch cable has a

white-brown tip and a brown-white ring? A Pair 1 B Pair 2 C Pair 3 D Pair 4"

"A - CORRECT ANSWER Which of the following is a measure of the amount of information

being transported over media? A Megabits B Volt-amperes C Kilowatt hours

"A - CORRECT ANSWER What is the maximum permissible amount of untwisting for category

5e cable and higher? A 12.7 mm (0.5") B 25 mm (1") C 38 mm (1.5") D 75 mm (3")"

"A - CORRECT ANSWER Which of the following is the first step of the emergency rescue

process? A Survey the scene B Contact 911 C Notify someone D Secure the area"

"C - CORRECT ANSWER What is the minimum inside bend radius for balanced twisted pair (

pair) cable? A 25 mm (1") B 50 mm (2") C 4 times the outside cable diameter D 15 times the outside cable diameter"

"A - CORRECT ANSWER Which of the following topologies is the recommended topology for

distribution systems in campus environments? A Hierarchical Star B Star

C Tree D Ring"

"A - CORRECT ANSWER A purple backboard should be used to identify ________?

A Common equipment B Demarcation point C Network connections D Horizontal cable"

"D - CORRECT ANSWER How far should the top of a ladder extend above the roofline?

A 0.3 m (1') B 0.5 m (1.6') C 0.6 m (2') D 0.9 m (3')"

"A - CORRECT ANSWER What grade of plywood is recommended for use with ICT systems?

A A/C

B A/D

C C/D

D B/C"

"D - CORRECT ANSWER What is the maximum number of work areas that a CP should serve?

A 2

C Ring D Tree"

"A - CORRECT ANSWER How long does it take someone to form a first impression?

A 10 to 15 seconds B 1 to 2 minutes C 5 to 10 minutes D 30 minutes to 1 hour"

"C - CORRECT ANSWER Which of the following is a floor serving space that serves as a point of

termination for horizontal and backbone cables? A EF B ER C TR D TE"

"D - CORRECT ANSWER The information transmitted by an ICT system can originate in two

fundamental forms: A Synchronous and asynchronous B Light and sound C Progressive and regressive D Analog and digital"

"C - CORRECT ANSWER What type of connector is used with ribbon cable?

A F Connector

B N Connector C Array D MPO"

"A - CORRECT ANSWER If you are working on a catwalk, you are required to wear _____?

A Full body harness and two lanyards B Nothing, your fine on the catwalk C Safety belt"

"B - CORRECT ANSWER Fall protection is required whenever a person is exposed to a fall

hazard more than ____? A 1.2 m (4') B 1.83 m (6') C 2.4 m (8') D 3 m (10')"

"A - CORRECT ANSWER What is the minimum recommended amount of vertical clearance for

open-top cable supports? A 75 mm (3") B 100 mm (4") C 125 mm (5") D 150 mm (6")"

"A - CORRECT ANSWER During the troubleshooting phase, what is the first step?

A Verify