A comprehensive set of questions and answers related to chimney and fireplace safety, covering topics such as flue sizing, inspection procedures, draft control, and combustion efficiency. It is a valuable resource for individuals seeking to understand the essential aspects of safe and efficient fireplace operation.

Typology: Exams

2024/2025

Available from 01/07/2025

tizian-kylan
tizian-kylan 🇺🇸

2.7

(21)

3.8K documents

1 / 18

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
CSIA TEST QUESTIONS AND ANSWERS
ALREADY PASSED
When a round flue is used for the lining of a fireplace chimney the proper fireplace opening to
flue size ratio should be ✔✔12:1
When unlined the smoke chamber walls shall be what thickness ✔✔8"
When the opening of the firebox is 6 square feet the extension of the hearth should be ✔✔20
inches
T or F the inner surfaces of the smoke chamber shall not be inclined more than 45 degrees from
vertical ✔✔True
A level 2 inspection inspection of accessible areas of attics basements and crawlspaces ✔✔True
The purpose of a heat reclaimer is to ✔✔Extract heat from the flue gases
What best describes the allowable free air space around a flue tile ✔✔1/4 inch to 4 inch
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12

Partial preview of the text

Download Chimney and Fireplace Safety: Questions and Answers and more Exams Welding Inspection Technologies in PDF only on Docsity!

CSIA TEST QUESTIONS AND ANSWERS

ALREADY PASSED

When a round flue is used for the lining of a fireplace chimney the proper fireplace opening to flue size ratio should be ✔✔12:

When unlined the smoke chamber walls shall be what thickness ✔✔8"

When the opening of the firebox is 6 square feet the extension of the hearth should be ✔✔ 20 inches

T or F the inner surfaces of the smoke chamber shall not be inclined more than 45 degrees from vertical ✔✔True

A level 2 inspection inspection of accessible areas of attics basements and crawlspaces ✔✔True

The purpose of a heat reclaimer is to ✔✔Extract heat from the flue gases

What best describes the allowable free air space around a flue tile ✔✔1/4 inch to 4 inch

Crickets are recommended whenever the chimney is ✔✔30" wide

The maximum allowable slope of an offset in a verticle flue is ✔✔30 degrees

The area of the spark arrestor must not be less than three times the net free area of the chimney flue ✔✔True

What is the minimum thickness of a wythe ✔✔4 inches nominal

chimney liners are listed to what standard ✔✔UL 1777

NFPA 211 recommends annual cleaning of chimneys fireplaces and vents ✔✔False

The horizontal length of a single wall connector to a natural drat chimney or vent serving a single appliance shall be not more than ______ of the height of the vertical height of the chimney ✔✔75 %

a level ______ inspection is done with ladders and common hand tools ✔✔ 2

Draft is the force or pressure difference between the inside and the outside of the venting system ✔✔true

NFPA 211 recommends chimney flues should be inspected ✔✔Annually

Two major factors that affect draft are ✔✔temperature differential and chimney height

what are factors of combustion efficiency ✔✔time turbulence and temperature

rabies is not carried by ✔✔Birds

what species carries histoplasmosis ✔✔Birds

what animal is known for roundworm ✔✔raccoons

what is NOT a step of a sweep ✔✔turn all gas appliances off

What is the proper class fire extinguisher for flammable liquids grease and oil ✔✔Class B

T or F - the area of a fireplace chimney flue cannot be greater than twice the area of the wood stove appliance outlet on an exterior chimney ✔✔True

a 24 gauge sheet metal panel with 1 inch airspace will reduce clearance to combustibles by ____ when used as a wall protector ✔✔66% ???

According to NFPA 211 solid fuel burning appliances can be install in a garage ✔✔

Fuel air and heat are required components of what ✔✔combustion

The maximum width for a type 1 industrial grade ladder rating is ✔✔250 pounds

where the trim of a mantel extends up to an 1 1/2 inch clearance to combustibles from the firebox opening should be at least ✔✔6 inches

connector pipe of thimble should extend into the chimney how far ✔✔flush with the interior flue wall

how many screws for connector pipe ✔✔ 3

the formula for determining the cross sectional area of a square or rectangular flue is? ✔✔

two major factors influence the mount of draft what are they ✔✔temperature difference the outside and flue gas temp and the height of the chimney

The height of the smoke chamber should be no taller than ✔✔

connectors should maintain a pitch or rise of _______ per foot of horizontal length of pipe from the appliance to the chimney or vent ✔✔1/4 inch

Thermal shock can be caused by ✔✔a sudden rise or drastic drop in temperature

T or F Vent and chimney connectors shall not be covered with insulation ✔✔True

Btus per cubic foot of gas ✔✔ 2500

Sensible heat is ✔✔heat that you can feel

T or F latent heat is heat you can feel ✔✔False

Natural gas has how many BTU per cubic foot of gas ✔✔ 1000

Propane gas has how many BTU per cubic foot of gas ✔✔ 2500

creosote is a ✔✔carcinogenic

How do you reset a stack control on an oil fired appliance ✔✔PUll the lever out 1/4 of an inch than release slowly

Backpuffing is ✔✔smoke coming into the room in short sharp burst

the temperature measured with a surface thermometer is roughly what percentage of the actual internal flue gas temperature ✔✔50%

Pellet fuel produces how much heat per pound ✔✔8200 BTUs

Cordwood produces how much heat per pound ✔✔

a heat exchanger is ✔✔an area of the appliance where heat is transferred to air or water

gases driven off from burning wood ignite at what temperature ✔✔1100 degrees

Complete combustion yields what ✔✔carbon dioxide water vapor and heat

residence time is ✔✔the amount of time smoke stays in the venting system

checking the fire stopping is part of a _______ inspection ✔✔level 3

checking that the wall pass through has adequate clearance is part of a _______ inspection ✔✔level 2

checking the basic appliance installation and connection is part of a ______ inspection ✔✔Level 1

Checking the size and suitability of flues for the connected appliances is part of a ________ inspection ✔✔Level 2

Checking the appliance and connector clearance is part of a _______ ✔✔Level 1 inspection

Checking the expansion joint the flue tile and the wash is part of a ________ inspection ✔✔level 2

when the fireplace opening is greater than 6 square feet the hearth must extend ______ to the front and ________ to the sides ✔✔20 and 12

a 3.5 inch thick brick wall protection system, installed with a 1-inch air space will reduce clearance to combustibles material by ✔✔

_________ Operated dampers shall not be places in chimney vents or connectors of stoker-fired liquid or gas burning appliances ✔✔Manually

There should be an air space between the flue tile and the inside of the chimney wall of at least _____ and no more than _______ ✔✔

ALl spaces between chimneys and the floors and ceilings through which the chimneys pass shall remain fully open but be ______ with non combustable material ✔✔

The maximum continuous flue gas temperature for a residential chimney should not exceed ✔✔1000 degrees

The minimum height for a chimney or vent above flue collat or draft hood is ✔✔3 feet

A chimney must be ______ taller than anything portion of any structure located within 10 feet of the chimney ✔✔24 inches

Interior residential chimneys shall be ______ where they extend through closets storage areas or habitable spaces ✔✔

what is the formula to determine the area of a circle ✔✔Radius X Radius X pi

if a mantel projects more than 3 inches it should be ✔✔12 " above the fireplace opening

how much can a nominal dimension vary ✔✔no more than 1/2 inch

According to IRC where there is no firebrick lining in the firebox the thickness of back and side walls shall not be less than ✔✔10"

the clearance to combustibles for a exterior masonry chimney is ✔✔1 inch

the clearance to combustibles for an interior masonry chimney is ✔✔2 inch

Are unlisted decorative shrouds allowed on zero clearance fireplaces ✔✔NO

3 and 1/2 inch thick masonry wall without ventilated air space allows you to reduce clearances by how much ✔✔33%

An exterior masonry chimney must have at least how many inches of clearance to a combustible wall ✔✔1 inch

unless a wood burning appliance is listed otherwise the floor protection should extend at least _____ inches on all sides of the appliance ✔✔18 inches

Mobile and manufactured homes must meet what standard ✔✔Stringent NFPA 211

T or F - vents are used for vented solid fuel burning appliances only ✔✔False

A draft hood should be installed on a wood stove when ✔✔

single wall connectors less than or equal to what diameter will be permitted to pass through a partition or wall. ✔✔

T or F a connector is a UL listed pipe to connect a fuel burning appliance to a chimney or vent ✔✔False

Smoke density is ✔✔Amount of unburned hydrocarbons in the flue gas

proper clearance to combustibles, inspection of accessible attics and rooftop inspection would be considered what level of inspection ✔✔Level 2

T or F - The net free area of the spark arrestor must not be less than 3 times the net free area of the chimney flue it serves ✔✔True

when installing stove pipe on a wood stove which end of the smoke pipe goes down toward the appliance ✔✔Male

The ideal moisture content of wood should range between ✔✔15 and 20%

The two major principles at work in a chimney are? ✔✔Draft and flow

Minimum air space allowed between the flue lining and the interior masonry wall is ✔✔not less than 1/2 inch