Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
A comprehensive set of questions and answers related to chimney and fireplace safety, covering topics such as flue sizing, inspection procedures, draft control, and combustion efficiency. It is a valuable resource for individuals seeking to understand the essential aspects of safe and efficient fireplace operation.
Typology: Exams
1 / 18
This page cannot be seen from the preview
Don't miss anything!
When a round flue is used for the lining of a fireplace chimney the proper fireplace opening to flue size ratio should be ✔✔12:
When unlined the smoke chamber walls shall be what thickness ✔✔8"
When the opening of the firebox is 6 square feet the extension of the hearth should be ✔✔ 20 inches
T or F the inner surfaces of the smoke chamber shall not be inclined more than 45 degrees from vertical ✔✔True
A level 2 inspection inspection of accessible areas of attics basements and crawlspaces ✔✔True
The purpose of a heat reclaimer is to ✔✔Extract heat from the flue gases
What best describes the allowable free air space around a flue tile ✔✔1/4 inch to 4 inch
Crickets are recommended whenever the chimney is ✔✔30" wide
The maximum allowable slope of an offset in a verticle flue is ✔✔30 degrees
The area of the spark arrestor must not be less than three times the net free area of the chimney flue ✔✔True
What is the minimum thickness of a wythe ✔✔4 inches nominal
chimney liners are listed to what standard ✔✔UL 1777
NFPA 211 recommends annual cleaning of chimneys fireplaces and vents ✔✔False
The horizontal length of a single wall connector to a natural drat chimney or vent serving a single appliance shall be not more than ______ of the height of the vertical height of the chimney ✔✔75 %
a level ______ inspection is done with ladders and common hand tools ✔✔ 2
Draft is the force or pressure difference between the inside and the outside of the venting system ✔✔true
NFPA 211 recommends chimney flues should be inspected ✔✔Annually
Two major factors that affect draft are ✔✔temperature differential and chimney height
what are factors of combustion efficiency ✔✔time turbulence and temperature
rabies is not carried by ✔✔Birds
what species carries histoplasmosis ✔✔Birds
what animal is known for roundworm ✔✔raccoons
what is NOT a step of a sweep ✔✔turn all gas appliances off
What is the proper class fire extinguisher for flammable liquids grease and oil ✔✔Class B
T or F - the area of a fireplace chimney flue cannot be greater than twice the area of the wood stove appliance outlet on an exterior chimney ✔✔True
a 24 gauge sheet metal panel with 1 inch airspace will reduce clearance to combustibles by ____ when used as a wall protector ✔✔66% ???
According to NFPA 211 solid fuel burning appliances can be install in a garage ✔✔
Fuel air and heat are required components of what ✔✔combustion
The maximum width for a type 1 industrial grade ladder rating is ✔✔250 pounds
where the trim of a mantel extends up to an 1 1/2 inch clearance to combustibles from the firebox opening should be at least ✔✔6 inches
connector pipe of thimble should extend into the chimney how far ✔✔flush with the interior flue wall
how many screws for connector pipe ✔✔ 3
the formula for determining the cross sectional area of a square or rectangular flue is? ✔✔
two major factors influence the mount of draft what are they ✔✔temperature difference the outside and flue gas temp and the height of the chimney
The height of the smoke chamber should be no taller than ✔✔
connectors should maintain a pitch or rise of _______ per foot of horizontal length of pipe from the appliance to the chimney or vent ✔✔1/4 inch
Thermal shock can be caused by ✔✔a sudden rise or drastic drop in temperature
T or F Vent and chimney connectors shall not be covered with insulation ✔✔True
Btus per cubic foot of gas ✔✔ 2500
Sensible heat is ✔✔heat that you can feel
T or F latent heat is heat you can feel ✔✔False
Natural gas has how many BTU per cubic foot of gas ✔✔ 1000
Propane gas has how many BTU per cubic foot of gas ✔✔ 2500
creosote is a ✔✔carcinogenic
How do you reset a stack control on an oil fired appliance ✔✔PUll the lever out 1/4 of an inch than release slowly
Backpuffing is ✔✔smoke coming into the room in short sharp burst
the temperature measured with a surface thermometer is roughly what percentage of the actual internal flue gas temperature ✔✔50%
Pellet fuel produces how much heat per pound ✔✔8200 BTUs
Cordwood produces how much heat per pound ✔✔
a heat exchanger is ✔✔an area of the appliance where heat is transferred to air or water
gases driven off from burning wood ignite at what temperature ✔✔1100 degrees
Complete combustion yields what ✔✔carbon dioxide water vapor and heat
residence time is ✔✔the amount of time smoke stays in the venting system
checking the fire stopping is part of a _______ inspection ✔✔level 3
checking that the wall pass through has adequate clearance is part of a _______ inspection ✔✔level 2
checking the basic appliance installation and connection is part of a ______ inspection ✔✔Level 1
Checking the size and suitability of flues for the connected appliances is part of a ________ inspection ✔✔Level 2
Checking the appliance and connector clearance is part of a _______ ✔✔Level 1 inspection
Checking the expansion joint the flue tile and the wash is part of a ________ inspection ✔✔level 2
when the fireplace opening is greater than 6 square feet the hearth must extend ______ to the front and ________ to the sides ✔✔20 and 12
a 3.5 inch thick brick wall protection system, installed with a 1-inch air space will reduce clearance to combustibles material by ✔✔
_________ Operated dampers shall not be places in chimney vents or connectors of stoker-fired liquid or gas burning appliances ✔✔Manually
There should be an air space between the flue tile and the inside of the chimney wall of at least _____ and no more than _______ ✔✔
ALl spaces between chimneys and the floors and ceilings through which the chimneys pass shall remain fully open but be ______ with non combustable material ✔✔
The maximum continuous flue gas temperature for a residential chimney should not exceed ✔✔1000 degrees
The minimum height for a chimney or vent above flue collat or draft hood is ✔✔3 feet
A chimney must be ______ taller than anything portion of any structure located within 10 feet of the chimney ✔✔24 inches
Interior residential chimneys shall be ______ where they extend through closets storage areas or habitable spaces ✔✔
what is the formula to determine the area of a circle ✔✔Radius X Radius X pi
if a mantel projects more than 3 inches it should be ✔✔12 " above the fireplace opening
how much can a nominal dimension vary ✔✔no more than 1/2 inch
According to IRC where there is no firebrick lining in the firebox the thickness of back and side walls shall not be less than ✔✔10"
the clearance to combustibles for a exterior masonry chimney is ✔✔1 inch
the clearance to combustibles for an interior masonry chimney is ✔✔2 inch
Are unlisted decorative shrouds allowed on zero clearance fireplaces ✔✔NO
3 and 1/2 inch thick masonry wall without ventilated air space allows you to reduce clearances by how much ✔✔33%
An exterior masonry chimney must have at least how many inches of clearance to a combustible wall ✔✔1 inch
unless a wood burning appliance is listed otherwise the floor protection should extend at least _____ inches on all sides of the appliance ✔✔18 inches
Mobile and manufactured homes must meet what standard ✔✔Stringent NFPA 211
T or F - vents are used for vented solid fuel burning appliances only ✔✔False
A draft hood should be installed on a wood stove when ✔✔
single wall connectors less than or equal to what diameter will be permitted to pass through a partition or wall. ✔✔
T or F a connector is a UL listed pipe to connect a fuel burning appliance to a chimney or vent ✔✔False
Smoke density is ✔✔Amount of unburned hydrocarbons in the flue gas
proper clearance to combustibles, inspection of accessible attics and rooftop inspection would be considered what level of inspection ✔✔Level 2
T or F - The net free area of the spark arrestor must not be less than 3 times the net free area of the chimney flue it serves ✔✔True
when installing stove pipe on a wood stove which end of the smoke pipe goes down toward the appliance ✔✔Male
The ideal moisture content of wood should range between ✔✔15 and 20%
The two major principles at work in a chimney are? ✔✔Draft and flow
Minimum air space allowed between the flue lining and the interior masonry wall is ✔✔not less than 1/2 inch