Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits 2025/2026
Typology: Exams
1 / 2
This page cannot be seen from the preview
Don't miss anything!
According to the NEC®, the ampacity of branch circuit conductors must be derated when there are more than how many current-carrying conductors in a raceway? - 3 Air conditioning overcurrent protective devices can never exceed what percentage of the motor-rated load current or the branch circuit selection current (whichever is greater)? - 225% Conductors must be derated when installed in conduit - on or above rooftops Continuous loads are calculated at what percentage of the maximum current rating of the overcurrent device? - 80% For a given load and length, the branch circuit voltage drop should not exceed - 3% For resistance welders, the rating for the overcurrent protection device should not exceed what percentage of the primary current rating of the welder? - 300% Show window lighting is calculated at 200VA per linear foot plus - 125% The allowable ampacity for eleven No. 12 THHN copper conductors in a cable must be adjusted by - 50% The load for 10' of multi-outlet assembly used to supply several loads simultaneously is
What is the load center distance for a 208V, four-wire, three-phase branch circuit with fixed noncontinuous loads from the source of 60A at 45', 40A at 60', 30A at 75', and 25A at 100' - 63.55' What is the load center length for a branch circuit consisting of noncontinuous loads of 125A at 80', 75A at 110', and 50A at 100'? - 93' What is the load center length for a branch circuit with noncontinuous loads of 20A at 60' and 50A at 125'? - 106.43' What is the load for 55' of show window using the linear foot method? - 13,750VA What is the motor full-load current for a motor with a nameplate rating of 50hp, 460V, 3Ø? - 65A What is the required circuit ampacity of a noncontinuous, single-phase load of 8.5kW at 277V? - 30.69A What is the required circuit ampacity for a noncontinuous, three-phase load of 6kW at 208V? - 16.65A What is the total ampacity for a 120V branch circuit consisting of four duplex receptacles rated noncontinuous duty and six duplex receptacles rated continuous duty? - 17.25A What is the total load required by the NEC® for two appliance branch circuits plus a laundry branch circuit? - 4,500VA What is the voltage drop for a 120V, single-phase, two-wire branch circuit, 100' long, using copper conductors of 6,530 circular mils with a noncontinuous load of 13A? 5.14V