Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

FDNYC G60 Practice Exam tested questions (latest 2025 / 2026) with verified answers, Exams of Safety and Fire Engineering

FDNYC G60 Practice Exam tested questions (latest 2025 / 2026) with verified answers FDNY G60 fire guard test questions G60 fire guard exam answers 2025 FDNY fire guard test prep 2026 latest G60 fire guard practice questions verified G60 fire guard answers FDNY G60 exam study guide G60 fire guard certification test 2025 G60 fire guard questions and answers FDNY G60 fire guard exam help

Typology: Exams

2024/2025

Available from 02/25/2025

smartdove-1
smartdove-1 🇺🇸

2

(2)

1.3K documents

1 / 15

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1 / 7
FDNYC G60 Practice Exam
Questions and Answers (Verified Answers)
1. All torch operators, an oxigen-fuel torch using any amount of oxigen
and flamable gas and fire guards must have a current✔✔✔ Certificate of
Fitness
2. The Certificate of Fitness holder✔✔✔ must regulate the pressure
and flow of oxygen and natural gas to each torch.
3. if the torch operator for jewelry manufacture involves✔✔✔ any oxygen
with any fuel gas containers, the operator must be a C of F holder.
4. A Certificate of Fitness Holder must keep his or her certificate✔✔✔ on
their person or otherwise readily available for inspection by any
representative of the fire Department
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download FDNYC G60 Practice Exam tested questions (latest 2025 / 2026) with verified answers and more Exams Safety and Fire Engineering in PDF only on Docsity!

FDNYC G60 Practice Exam

Questions and Answers (Verified Answers)

  1. All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current✔✔✔ Certificate of Fitness
  2. The Certificate of Fitness holder✔✔✔ must regulate the pressure and flow of oxygen and natural gas to each torch.
  3. if the torch operator for jewelry manufacture involves✔✔✔ any oxygen with any fuel gas containers, the operator must be a C of F holder.
  4. A Certificate of Fitness Holder must keep his or her certificate✔✔✔ on their person or otherwise readily available for inspection by any representative of the fire Department
  1. The easiest way to extinguish a fire caused by a leak is to✔✔✔ close the shutoff valve
  2. Permits issued by the FDNY are required to conduct the following hot work✔✔✔✔✔✔ storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF.
  3. For LPG, 400 SCF is✔✔✔ approximately 47 lbs
  4. the number of LPG containers for the storage, use, handling or transporta- tion, requiring a permit✔✔✔ 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont.
  1. Hot work authorization should be issued by the responsible person, and it✔✔✔ must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete
  2. FDNY permits✔✔✔ will be posted in a central location and recorded in a log book to assist in the coordination of construction related activities.
  3. CNG✔✔✔ Compressed Natural Gas.
  4. For Citywide hot work operations, the Owner of the premises must be no- tified in writing at least hours in advance prior to work beginning.✔✔✔ 48
  5. A class A fire extinguisher fights fires from✔✔✔ Paper
  6. How old must a candidate be in order to earn a Certificate of Fitness? ✔✔✔ 18 Years Old
  1. What type of fire is a Class B fire extinguisher used on?✔✔✔ Oil
  2. Examples of combustibles include✔✔✔ Newspaper
  3. An example of a flammable material would be✔✔✔ Gasoline
  4. Fire extinguishers must be inspected once every✔✔✔ Month
  5. A work area should be✔✔✔ Well Ventilated
  6. A type C fire involves✔✔✔ Live electrical equipment
  7. Automatic sprinkler heads should be✔✔✔ covered by a damp cloth and removed after hot work
  8. A permit is required for storing a flammable gas in excess of✔✔✔ 400 scf
  1. A hot work permit is required for✔✔✔ welding
  2. A spark producing tool✔✔✔ requires a Fire Guard
  3. Soldering and brazing temperatures are typically✔✔✔ 840 degrees Fahrenheit
  4. Oxy-Acetylene can generate a temperature of up to✔✔✔ 6000 degrees Fahren- heit
  5. An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a✔✔✔ Hot Work Area
  6. A person holding a Certificate of Fitness who is trained and responsible for maintaining a fire watch is known as a✔✔✔ Fire Guard
  7. Most fires are the result of✔✔✔ sparks
  8. What should you do if ice buildup occurs on the gas cylinder itself? ✔✔✔ call 911 immediately
  9. If a Certificate of Fitness holder discovers that an oxygen regulator is defective, they should✔✔✔ take it out of service 45. If a gas container is unmarked, the certificate of fitness holder should✔✔✔ - take the cylinder out of service
  10. What tank condition would be cause to remove it from service? ✔✔✔ the pressure relief valve shows visible damage
  1. A control valve should be✔✔✔ opened by hand
  2. Persons conducting Torch Operations must possess a current✔✔✔ G- 60 Cer- tificate of Fitness
  3. A rapid, persistent chemical reaction that releases heat and light, espe- cially the burning of a combustible substance in the presence of oxygen.✔✔✔ A Fire
  4. A class B fire extinguisher fights fires from✔✔✔ oil
  5. A written statement issued by the commissioner certifying that the per- son to whom it is issued has passed an examination as to his or her quali- fications or is otherwise deemed qualified to use or supervise the storage, handling and use of a material✔✔✔ Certificate of Fitness
  6. What type of fire is a Class A fire extinguisher used on?✔✔✔ cardboard
  7. An example of a flammable material would be✔✔✔ kerosene
  8. Fire extinguishers must be maintained by a W-96 Certificate of Fitness holder every✔✔✔ year
  1. To prevent injury hoses should be✔✔✔ As short as practical.
  2. The oxygen cylinder✔✔✔ is made of steel and contains 100% oxygen.
  3. A compressed gas container must✔✔✔ Not be rolled on its side.
  4. An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a✔✔✔ Hot work area.
  5. Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of✔✔✔ 20 feet.
  6. Most fires are the result of✔✔✔ Sparks.
  7. Sparks and pieces of hot metal are the source of ignition in about of fires in industrial occupancies.✔✔✔ 60.
  8. Under no circumstances can hot work be performed within feet of flammable or explosive materials.✔✔✔ 35.
  1. If torch operation is to be discontinued for a period of , the torch valve must be closed and the gas supply to the torch must be completely shut.✔✔✔ One hour or more.
  2. A torch should be ignited by using a✔✔✔ Friction device.
  3. Why should oil or grease not be used near oxygen?✔✔✔ It might cause an explosion.
  4. How long is a site permanent specific permit to store flammable gases valid for?✔✔✔ 30 days
  5. How many Fire Guards are required on a job site that has 3 torches in operation?✔✔✔ One per torch and additional one stationed on the floor below.
  6. Portable LPG containers greater than must not be stored in residential occupancies.✔✔✔ 16.4 oz.
  7. An oxygen cylinder may store gas at pressure up to✔✔✔ 2200 psi.
  8. A Responsible Person is one who is✔✔✔ trained in the fire safety hazards associated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises.
  9. A designated Hot Work area must be at least feet away from combustible materials.✔✔✔ 35.
  1. Fire Drill✔✔✔ A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly and expeditious in-building relocation, partial evacuation or evacuation, as applicable to the occupancy or building type, in accordance with the fire safety and evacuation plan.
  2. shall not be considered a fire✔✔✔ flame used in any lawful, properly operating device, equipment or system or other controlled setting.
  3. Fire Watch✔✔✔ A temporary measure intended to ensure continuous and system- atic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire and notifying the department.
  4. Hot Work✔✔✔ Cutting, welding, thermit welding, brazing, soldering, grinding, ther- mal spraying, thawing pipe, cad welding, installation of torch-applied system, or any other similar operation or activity.
  5. Torch Applied Roof-System✔✔✔ Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion.
  6. Egress✔✔✔ A means of exit from a fire or other emergency.
  7. Single Action fire alarm pull station✔✔✔ requires the user to simply

pull a lever or break glass to activate the alarm. This type is commonly used indoors.

  1. Double Action fire alarm pull station✔✔✔ Double Action fire alarm pull station- requires the user to take two steps in order to activate the alarm such as lifting a cover and then pulling a lever. This type of alarm is commonly used outside.
  2. All gas containers and the related equipment✔✔✔ must be protected from extreme temperature and physical damage.
  3. Any single standard portable LPG container must not exceed✔✔✔ 100 lbs in weight.
  4. Any single CNG container must not exceed✔✔✔ 381 SCF.
  5. Permits shall be readily available on the premise for inspection by✔✔✔ Fire Department representatives.
  6. NFPA stands for✔✔✔ National Fire Protection Association.
  7. Most common fuel gases used in blowtorches are✔✔✔ LPG (e.g. butane, propane), natural gas (methane) (either CNG or piped natural gas).
  8. A fire guard is responsible for✔✔✔ overseeing torch operations.