A comprehensive set of practice questions and answers related to fdnyc g60 regulations, focusing on fire safety and hot work procedures. It covers topics such as hot work permits, fire extinguishers, flammable materials, and the responsibilities of certificate of fitness holders. Valuable for individuals seeking to understand and comply with fire safety regulations in new york city.

Typology: Exams

2024/2025

Available from 04/07/2025

Shantelle
Shantelle ๐Ÿ‡บ๐Ÿ‡ธ

5

(2)

3K documents

1 / 11

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
FDNYC G60 With 112 Practice Exam
a result of welding is called a - โœ” โœ” Hot work area.
Fuel gas or oxygen containers in storage must be separated from any
combustible materials by a minimum distance of - โœ” โœ” 20 feet.
Most fires are the result of - โœ” โœ” Sparks.
Sparks and pieces of hot metal are the source of ignition in
about______ of fires in industrial occupancies. - โœ” โœ” 60.
Under no circumstances can hot work be performed within _____ feet
of flammable or explosive materials. - โœ” โœ” 35.
If torch operation is to be discontinued for a period of ___________,
the torch valve must be closed and the gas supply to the torch must be
completely shut. - โœ” โœ” One hour or more.
A torch should be ignited by using a - โœ” โœ” Friction device.
Why should oil or grease not be used near oxygen? - โœ” โœ” It might
cause an explosion.
How long is a site permanent specific permit to store flammable gases
valid for? - โœ” โœ” 30 days
How many Fire Guards are required on a job site that has 3 torches in
operation? - โœ” โœ” One per torch and additional one stationed on the
floor below.
Portable LPG containers greater than ______ must not be stored in
residential occupancies. - โœ” โœ” 16.4 oz.
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download FDNYC G60 With 112 Practice Exam: Fire Safety and Hot Work Regulations and more Exams Engineering in PDF only on Docsity!

FDNYC G60 With 112 Practice Exam

a result of welding is called a - โœ” โœ” Hot work area. Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of - โœ” โœ” 20 feet. Most fires are the result of - โœ” โœ” Sparks. Sparks and pieces of hot metal are the source of ignition in about______ of fires in industrial occupancies. - โœ” โœ” 60. Under no circumstances can hot work be performed within _____ feet of flammable or explosive materials. - โœ” โœ” 35. If torch operation is to be discontinued for a period of ___________, the torch valve must be closed and the gas supply to the torch must be completely shut. - โœ” โœ” One hour or more. A torch should be ignited by using a - โœ” โœ” Friction device. Why should oil or grease not be used near oxygen? - โœ” โœ” It might cause an explosion. How long is a site permanent specific permit to store flammable gases valid for? - โœ” โœ” 30 days How many Fire Guards are required on a job site that has 3 torches in operation? - โœ” โœ” One per torch and additional one stationed on the floor below. Portable LPG containers greater than ______ must not be stored in residential occupancies. - โœ” โœ” 16.4 oz.

An oxygen cylinder may store gas at pressure up to - โœ” โœ” 2200 psi. A Responsible Person is one who is - โœ” โœ” trained in the fire safety hazards associated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises. A designated Hot Work area must be at least_______ feet away from combustible materials. - โœ” โœ” 35. For all Hot Work, inspections must be completed_______ after completion of torch operations. - โœ” โœ” 30 minutes. A minimum ___________ rating Fire Extinguisher must be readily accessible within ________ of the hot work location for torch operations. - โœ” โœ” 2-A:20-B:C, 30 feet. For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must be readily accessible within ________. - โœ” โœ” 3-A: 40-B:C, 30 feet. Empty compressed gas cylinders - โœ” โœ” Should be handled in the same manner as full ones. Panic Bar - โœ” โœ” A device fitted on the inside of a door that would allow a person to push against a door to open it. A type of valve typically used in sprinkler systems - โœ” โœ” OS & Y Valve- Outside Screw and Yoke Valve. Fire Drill - โœ” โœ” A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly

the number of LPG containers for the storage, use, handling or transportation, requiring a permit - โœ” โœ” 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF - โœ” โœ” must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule. Site-specific permit - โœ” โœ” may be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only A city-wide permit is valid - โœ” โœ” up to 30 days Permits shall be - โœ” โœ” readily available on the premise for inspection by Fire Department representatives. Hot work authorization should be issued by the responsible person, and it - โœ” โœ” must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete

FDNY permits - โœ” โœ” will be posted in a central location and recorded in a log book to assist in the coordination of construction related activities. CNG - โœ” โœ” Compressed Natural Gas. For Citywide hot work operations, the Owner of the premises must be notified in writing at least _____ hours in advance prior to work beginning. - โœ” โœ” 48 A class A fire extinguisher fights fires from - โœ” โœ” Paper How old must a candidate be in order to earn a Certificate of Fitness? - โœ” โœ” 18 Years Old What type of fire is a Class B fire extinguisher used on? - โœ” โœ” Oil Examples of combustibles include - โœ” โœ” Newspaper An example of a flammable material would be - โœ” โœ” Gasoline Fire extinguishers must be inspected once every - โœ” โœ” Month A work area should be - โœ” โœ” Well Ventilated A type C fire involves - โœ” โœ” Live electrical equipment Automatic sprinkler heads should be - โœ” โœ” covered by a damp cloth and removed after hot work A permit is required for storing a flammable gas in excess of - โœ” โœ” 400 scf Acetylene burns at - โœ” โœ” 3000 degrees Fahrenheit

What should you do if ice buildup occurs on the gas cylinder itself? - โœ” โœ” call 911 immediately If a Certificate of Fitness holder discovers that an oxygen regulator is defective, they should - โœ” โœ” take it out of service If a gas container is unmarked, the certificate of fitness holder should - โœ” โœ” take the cylinder out of service What tank condition would be cause to remove it from service? - โœ” โœ” the pressure relief valve shows visible damage A control valve should be - โœ” โœ” opened by hand Persons conducting Torch Operations must possess a current - โœ” โœ” G-60 Certificate of Fitness A rapid, persistent chemical reaction that releases heat and light, especially the burning of a combustible substance in the presence of oxygen. - โœ” โœ” A Fire A class B fire extinguisher fights fires from - โœ” โœ” oil A written statement issued by the commissioner certifying that the person to whom it is issued has passed an examination as to his or her qualifications or is otherwise deemed qualified to use or supervise the storage, handling and use of a material - โœ” โœ” Certificate of Fitness What type of fire is a Class A fire extinguisher used on? - โœ” โœ” cardboard An example of a flammable material would be - โœ” โœ” kerosene

Fire extinguishers must be maintained by a W-96 Certificate of Fitness holder every - โœ” โœ” year A type D fire involves - โœ” โœ” Combustible Metals A type of clothing that should not be worn when performing torch operations is - โœ” โœ” Frayed Clothing. A flame going out unexpectedly and creating a popping sound is known as - โœ” โœ” Backfire. When a cutting or welding flame burns inside a torch is known as - โœ” โœ” Flashback. To check for a leak one should - โœ” โœ” Use a soap and water solution. A fire extinguisher must be mounted - โœ” โœ” so that the top is not more than 5 feet off the floor A work area should be - โœ” โœ” Well ventilated. To extinguish a fire - โœ” โœ” Always approach the fire from upwind. How should a gas cylinder be stored? - โœ” โœ” Upright and not on shelves. In the case of any fire, - โœ” โœ” The FDNY must be notified. Acetylene valves should not be opened more than - โœ” โœ” 1 1/2 turns "SCF" stands for - โœ” โœ” Standard Cubic Feet A Certificate of Fitness Holder must keep his or her certificate - โœ” โœ” On their person.

Egress - โœ” โœ” A means of exit from a fire or other emergency. Single Action fire alarm pull station - โœ” โœ” requires the user to simply pull a lever or break glass to activate the alarm. This type is commonly used indoors. Double Action fire alarm pull station - โœ” โœ” Double Action fire alarm pull station- requires the user to take two steps in order to activate the alarm such as lifting a cover and then pulling a lever. This type of alarm is commonly used outside. All gas containers and the related equipment - โœ” โœ” must be protected from extreme temperature and physical damage. Any single standard portable LPG container must not exceed - โœ” โœ” 100 lbs in weight. Any single CNG container must not exceed - โœ” โœ” 381 SCF. Permits shall be readily available on the premise for inspection by - โœ” โœ” Fire Department representatives. NFPA stands for - โœ” โœ” National Fire Protection Association. Most common fuel gases used in blowtorches are - โœ” โœ” LPG (e.g. butane, propane), natural gas (methane) (either CNG or piped natural gas). A fire guard is responsible for - โœ” โœ” overseeing torch operations. The pre-hot work check must be conducted by - โœ” โœ” the responsible person before hot work is authorized and at least once per day.

The check reports must be kept at the work site - โœ” โœ” maintained on the premises for a minimum of 48 hours after work is complete. Exhaust fans - โœ” โœ” may be used to draw the fumes away from the work area The workers should - โœ” โœ” wear flame resistant gloves and aprons and should not be worm Clothing with pockets or cuffs