Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
A detailed architectural plan, focusing on the specifications for a building project. It includes legends for brick masonry walls, floor levels, and road levels, along with schedules for windows and doors, detailing their sizes, materials, and descriptions. The plan also incorporates notes on dimensions, drawing interpretations, and finish ground levels, providing a comprehensive guide for construction and engineering teams. Useful for architecture students and professionals. (410 characters)
Typology: Schemes and Mind Maps
1 / 1
This page cannot be seen from the preview
Don't miss anything!
4770 x 8740 41.68 SQM.
4770 x 2170 10.35 SQM.
3305 x 2170 7.17 SQM.
2305 x 2170 5.00 SQM.
2305 x 1470 3.38 SQM.
3200 x 3170 10.14 SQM. 200 MM SUNK SLAB
3200 x 3170 10.14 SQM. DISABLED 200 MM SUNK SLAB TOILET 2200 x 2400 5.28 SQM.
4840 x 4320 20.90 SQM.
4840 x 11140 53.91 SQM.
5700 x 11420 65.09 SQM.
9870 x 11140 109.61 SQM.
6000 x 4370 26.22 SQM.
7405
7405
2535 x 1370 3.47 SQM.
3535 x 4370 15.44 SQM.
3430 x 9200 31.55 SQM.
1980 x 9200 18.21 SQM.
3740 x 2420 9.05 SQM.
14500 x 2400 34.80 SQM.
2200 x 1510 3.32 SQM.
10050 x 1500 15.07 SQM.
3200 x 855
3200 x 855
1570 x 855
1875 x 1650 3.09 SQM.
1495 x 1720
1000 x 1120
HVAC SHAFT1000 x 2790
3210 x 4140 13.28 SQM.
3200 x 855
3200 x 855
2300 x 610
PLATFORM1500 x 20003.00 SQM.
1570 x 855
5840 x 4140 24.17 SQM.
2535 x 1200 3.04 SQM.
WD14a
7405
7405
06 WD14a
COMPOUND WALL
TYPE - 2 Coal BerthDOCK BASIN (-)15.7 m
GC/MP BerthGC/MP Berth GC/MP Berth
SUB STATION-2(15.65mx10.4m) SUB STATION-3(15.65mx10.4m)
SUB-STATION-1(15.65mx10.4m)^ HM1^ ADMINISTRATIONBUILDING (72mX50m)^ WEIGH BRIDGE^5000 PORTOPRATIONBUILDING(20.4mX13.23m)(10mX10m)^ GUARD ROOMWEIGH BRIDGEGUARD ROOMGUARD ROOM^50005000 STP^ UNDERGROUNDWATER TANK(24.35mX15.35m) PUMP HOUSE(12.35mX6m)^ OVER HEADWATER TANK FIRE STATION 200 M X 200 M^ MAINRECEIVINGSUBSTATION
PROPOSEDGROYNES
NORTH BREAKWATER
A SOUTH BREAKWATER (2075m)
B
C D
A
Shore line
Dia 450 m
APPROACH CHANNEL-17.1 m (-)16.4mTURNINGCIRCLE
WORKSHOP(110.4mX42.6m)^ ETP(10mX10m)
GUEST HOUSE(52mX12m)
TITLE
SCALE
PROJECT NAME
EMPLOYER
CHECKED BY APPROVED BY
DRAWING NO.
DRAWN BY
REVISION
DATE REF.
502-505, 5th Floor, Platinum Techno Park Plot 17 & 18, Sector 30 A, Vashi Navi Mumbai - 400 703, INDIA Tel +91 (0) 22 61395000 Email info.india@rhdhv.com www.royalhaskoningdhv.com
SUITABLILITY
CONTRACTOR'S DESIGNER
EPC-CONTRACTOR
ENGINEER
C HaskoningDHV India Pvt. Ltd.
REV DATE DESCRIPTION DRW CHK APR
REVISIONS
P01 15.03.2023 ISSUED FOR APPROVAL ZR GS BD
P02 08.05.2023 ISSUED FOR APPROVAL ZR GS BD
KEY PLAN