- Where you have found evidence of foo2ng se5lement, how can you predict whether there will be further se5lement? (a) You can count the number of planes of movement. (b) You can determine the type of founda2on material. (c) You cannot predict se5lement from a single inspec2on. (d) You can determine the depth of the foo2ng. You cannot predict se5lement from a single inspec2on
- You typically iden2fy a Freon leak (a) As an oil stain (b) As refrigerant coming out of the Freon line in the form of a cold mist. (c) By the strong odor. (d) By looking for evidence of ice along the refrigerant lines As an oil stain
- Typical wood frame wall assemblies include all of the following components EXCEPT. (a) Studs (b) Bridging (c) Sheathing (d) Siding Bridging
HL7 MOCK TEST 2- 1 FINAL
EXAM WITH 100% VERIFIED
SOLUTIONS 2024/
- All of the following are common approaches to improving chimney draN EXCEPT (a) Adding a draN inducer fan. (b) Adding a rain cap. (c) Extending the chimney upward. (d) Resloping the cap. Resloping the cap
- All of the following statements are true of shrinkage cracks EXCEPT that (a) Shrinkage cracks do not typically go into the foo2ngs. (b) Shrinkage cracks do not necessarily have corresponding cracks elsewhere in the building. (c) Ver2cal shear is associated with shrinkage cracks. (d) Shrinkage cracks are common with poured concrete founda2on walls. Ver2cal shear is associated with shrinkage cracks
- Which of the following is NOT typically a component of a private water supply system? (a) Foot valve (b) Pump (c) Pressure regulator (d) Pressure tank Pressure regulator
- Split-system, air-cooled, central air-condi2oning systems have how many fans?
(b) If the wall has moved inward, the cracks would typically be wider on the inside face. (c) If the wall has moved inward, cracks will typically be wider on the outside face. (d) You should not be concerned unless the crack is at least ¼ in width. If the wall has moved inward, the cracks would typically be wider on the inside face
- On most steep roofs, exposed fasteners are (a) Used for anchorage against wind. (b) A sign of poor installa2on. (c) A sign of good installa2on. (d) Used to prevent ice dams. A sign of poor installa2on
- All of the following are slab-on-grade-construc2on techniques EXCEPT (a) Monolithic slab. (b) Floa2ng slab. (c) Inverted slab. (d) Reinforced slab. Inverted slab
- Masonry chimneys should have a clearance from combus2ble framing members of (a) 1 inch. (b) 2 inches.
(c) 4 inches. (d) 12 inches. 2 inches
- Efflorescence (a) Is associated with water moving through masonry walls. (b) Can only appear on the cold side of a wall. (c) Only occurs in freezing climates. (d) Is an organic growth. Is associated with water moving through masonry walls
- On a conven2onal split-system air-condi2oning system, the high-pressure side is the por2on of the refrigerant line from the (a) Compressor to the expansion device. (b) Metering device to the evaporator coil. (c) Expansion device to the compressor. (d) Evaporator to the compressor. Evaporator to the compressor
- The presence of step flashing on an asphalt shingle roof can typically be verified by (a) Looking at the counter flashing. (b) Knowing the age of the shingles on the roof. (c) Knowing the number of layers of shingles on the roof. (d) LiNing the shingles adjacent to the chimney or wall LiNing the shingles adjacent to the chimney or wall
(a) An opportunity for be5er communica2on. (b) You can charge a premium for allowing clients to a5end. (c) That showing is be5er than telling. (d) You have the opportunity to adjust expecta2ons. You can charge a premium for allowing clients to a5end
- The flame of the leN burner in a two-burner conven2onal efficiency furnace touches the heat exchanger only when the blower is running. What is likely to be the problem? (a) The heat exchanger is cracked on the leN side. (b) The heat exchanger is cracked on the right side. (c) The leN burner is dirty. (d) The leN burner is misaligned. The heat exchanger is cracked on the leN side
- What would you do if you saw that a roof truss had been cut? (a) Advise client to sister a 2 x 4 piece over the cut. The sistered piece should extend at least three feet on either side of the cut. (b) Advise client that cuts in trusses are not a problem. (c) Look for other signs of distress and, if none, do nothing. (d) Advise further evalua2on by a specialist. Advise further evalua2on by a specialist
- CPVC water pipe may not be used for hot and cold supply lines (a) In single-family residences. (b) In mul2family residences.
(c) Inside a building. (d) Below grade. In mul2family residences
- Garage door problems include all of the following EXCEPT (a) A seven-inch step down into garage. (b) Poor weatherstripping. (c) That it has no self-closer. (d) If it opens into a bedroom. A seven-inch step down into garage
- Which of the following statements is TRUE? (a) Uniform se5lement is most oNen the result of building on undisturbed soils. (b) Expansive soils expand as they dry. (c) Lowering the basement floor to the top of the foo2ng can cause se5lement where there was no se5lement ini2ally. (d) Uniform se5lement may stress u2lity pipes. Uniform se5lement may stress u2lity pipes.
(c) Soil below is disturbed. (d) Beams are undersized. Soil below is disturbed
- Amc insula2on may be wet as a result of any of the following EXCEPT (a) Insula2on that is too close to chimneys. (b) A roof leak. (c) Condensa2on. (d) An exhaust fan discharging directly into the insula2on. Insula2on that is too close to chimneys.
- These products are all asphalt based EXCEPT for (a) Roofing cement. (b) Asphalt cement. (c) Plas2c cement. (d) Caulking. Caulking
- All of the following are true with EIFS EXCEPT that (a) It is typically applied directly to a polystyrene insula2on board. (b) It is typically a two-coat process. (c) A fiber glass mesh replaces wire lath. (d) The finish coat is thicker than with tradi2onal stucco. The finish coat is thicker than with tradi2onal stucco
- The introductory discussion should (a) Help to adjust the expecta2ons of the client.
(b) Establish your credibility with the use of a number or technical terms (c) Include instruc2ons for your clients to avoid ques2ons since this will pull you from your rou2ne. (d) Include ques2ons about the clients preferred order for inspec2ng the components of the home. Help to adjust the expecta2ons of the client
- Which of the following statements is FALSE with respect to electric water heaters? (a) Most water heaters have two elements. (b) The upper element usually comes on first (c) The upper element has priority (d) It can be difficult to tell if one of the two elements is burned out The upper element usually comes on first
- If you drilled a hole through a properly laid asphalt-shingle roof, how many shingles would you go through? (a) One (b) Two (c) Three (d) Four Two
- Which phrase does NOT describe a home inspec2on? (a) Field review of performance (b) Evalua2on of physical condi2on
- Which of the following statements about home inspectors' liability is TRUE? (a) As long as you provide wri5en reports, you have no liability. (b) Your liability is greater if your buyers' expecta2ons are not realis2c. (c) Home improvement contractors play no part in home inspector liability. (d) The last-one-in syndrome helps to reduce liability. Your liability is greater if your buyers' expecta2ons are not realis2c
- The condensate drain pan or tray on a split-system air condi2oner is typically located below the (a) Compressor. (b) Condenser coil. (c) Evaporator coil. (d) Expansion device. Evaporator coil
- The most serious implica2on of a leaking humidifier is (a) Flooding. (b) Rus2ng of the furnace cabinet (c) Rus2ng of the heat exchanger. (d) Shor2ng out the furnace wiring. Rus2ng of the heat exchanger
- For a galvanized-steel roof (a) The surface should be coated with mas2c to extend the useful life. (b) Pain2ng the surface is one acceptable way of protec2ng the surface. (c) The metal should be held down with copper nails or screws to prevent
corrosion. (d) Both a and c are true. Pain2ng the surface is one acceptable way of protec2ng the surface.
- The main service fuses have been installed with the labels facing backward, such that you cannot read their ra2ng. No other markings are visible. You should (a) Turn off the house power and remove a fuse to check its ra2ng. (b) Measure the diameter of the fuse body to determine its ra2ng. (c) Report that the main service fuse ra2ng was not determinable. (d) Carefully insert your inspec2on mirror un2l the label is visible, then read the ra2ng from the label. Report that the main service fuse ra2ng was not determinable
- ANer you turn an electric baseboard heater on, how long should it take for the heater to get warm? (a) Less than 10 seconds (b) Less than 1 minute (c) Less than 5 minutes (d) Less than 10 minutes Less than 1 minute
- Which statement about crawlspaces is FALSE? (a) Crawlspaces can be heated or unheated. (b) The floor will be more comfortable if the crawlspace floor is insulated. (c) It is typically easier to insulate the walls than the crawlspace ceiling. (d) Insula2ng the walls can be done on the inside or outside
(a) The shingles are suffering freeze-thaw damage. (b) This is a common cosme2c condi2on that does not affect performance or life expectancy. (c) There is a possible manufacturing defect and life expectancy may be shortened. (d) This is a result of expansion and contrac2on of waferboard sheathing as a result of changes in humidity. There is a possible manufacturing defect and life expectancy may be shortened
- Common problems with clay or slate shingles include all of the following EXCEPT (a) Missing shingles. (b) Loose shingles. (c) Buckled shingles (d) Broken shingles. Buckled shingles
- On which roof are exposed fasteners most likely to be acceptable? (a) Metal (b) Clay (c) Concrete (d) Asphalt Metal
- How thick (maximum) should a creosote deposit in a wood stove be before it is removed?
(a) ¼ inch (b) ½ inch (c) ¾ inch (d) 1 inch ¼ inch
- Spalling and mortar damage near the bo5om of an exterior masonry column would likely be the result of (a) Eccentric loads (b) Frost heave (c) Soil erosion (d) Freeze/thaw cycles Freeze/thaw cycles
- Recommenda2ons to a client regarding brick cracks may include all of these EXCEPT to (a) Caulk them (b) Ignore them (c) Monitor them (d) Call in a specialist for further advice Caulk them
(c) Support window sills (d) Support beams Support lintels
- Wood deteriora2on is typically discovered during a home inspec2on by (a) Probing with an awl or similar tool (b) Visual observa2on (c) Tapping with a hammer (d) Both a and b Both a and b
- Common and dangerous cracks in the hearth of a wood-burning fireplace are oNen found (a) At the back of the hearth (b) Between the hearth and hearth extension (c) At the front of the hearth extension (d) At the sides of the hearth extension Between the hearth and hearth extension
- There are two layers of shingles on the roof, with the most recent installa2on less than two-years-old. At the chimney, the original steel flashings are rusted. The shingles are sealed to the older metal with asphalt cement. The roofer should have (a) Used caulking instead of asphalt cement (b) Installed new flashings (c) Stripped off the old shingles first (d) Replaced only the flashings that are rusted through
Installed new flashings
- Masonry veneer walls are (a) Supported with header courses (b) Hung on studs (c) Water2ght (d) Bri5le Bri5le
- You can check the thickness of the flooring and the subfloor material by (a) Referring to building plans (b) LiNing out a supply air register (c) Measuring the overall floor thickness and subtrac2ng the joists (d) Drilling a small pilot hole in an inconspicuous spot LiNing out a supply air register
- You no2ce a wooden post as the support for the service drop. You should (a) Recommend replacing it right away with a steel mast. (b) Check for rot, damage, or movement (c) Assume that you'll find obsolete equipment inside the house (d) Tug on the service drop wires to make sure the mast doesn't give Check for rot, damage, or movement
- Rope wicks in veneer walls (a) Are be5er than weep holes (b) Are oNen used in place of weep holes