Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

ILE FINAL EXAM PREP 2025/ACTUAL 210 EXAM QUESTIONS &ANSWERS|2025-2026|ILE FINAL EXAM PREP, Exams of Public Health

ILE FINAL EXAM PREP 2025/ACTUAL 210 EXAM QUESTIONS &ANSWERS|2025-2026|ILE FINAL EXAM PREP|ALREADY GRADED A+

Typology: Exams

2024/2025

Available from 06/05/2025

calleb-kahuro
calleb-kahuro 🇺🇸

5

(5)

1.3K documents

1 / 63

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
-ANS:->>>-- C. send it to the manufacture for repair and refurbishment
D. recommend medical referral
C. send it to the manufacture for repair and refurbishment
B. send it to an all-make repair facility
adjustments until the PT reports improvement.
connected the hearing instrument to the manufacture's software and mak
A.
D. Tells them that they will not work on hearing aids that are 5 years old -
C. return it to the PT and have them complete APHAB
When a hearing instrument is returned from repair, the hearing instrument
specialist should
A. preform an electro acoustical analysis to verify that its performance is at
specifications
B. call the family and have them just pick it up- you don't need to see the PT
ILE FINAL EXAM PREP 2025/ACTUAL 210 EXAM
QUESTIONS &ANSWERS|2025-2026|ILE FINAL
EXAM PREP|ALREADY GRADED A+
The PT brings in their 4 year old high end digital signal processing hearing
instrument because its not working at all. It is out of warranty. The entire source
of the problem has not been found and the hearing instrument is still not
working. At this point the hearing instrument specialist has no choice but to
A. recommend that they purchase a new set
D. preform ear measurements on the hearing instrument before the PT arrives to
pick it up. -ANS:->>>-- A. preform an electro acoustical analysis to verify that
its performance is at specifications
A new PT makes an appointment for a repair of their older BTE. There is an
accumulation of wax and debris in the tubing. Once the tubing is changed,
feedback is eliminated and a sound check indicates that the aid is working nicely.
The new PT reports that they need the performance adjusted, they're just not
hearing too well. The hearing aid specialist.
es
ds
1
C. preforms a hearing test, reprograms the instrument, and preforms real-ear
Has them make a return appointment for an evaluation for new hearing ai
B.
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23
pf24
pf25
pf26
pf27
pf28
pf29
pf2a
pf2b
pf2c
pf2d
pf2e
pf2f
pf30
pf31
pf32
pf33
pf34
pf35
pf36
pf37
pf38
pf39
pf3a
pf3b
pf3c
pf3d
pf3e
pf3f

Partial preview of the text

Download ILE FINAL EXAM PREP 2025/ACTUAL 210 EXAM QUESTIONS &ANSWERS|2025-2026|ILE FINAL EXAM PREP and more Exams Public Health in PDF only on Docsity!

  • ANS:->>>-- C. send it to the manufacture for repair and refurbishment D. recommend medical referral C. send it to the manufacture for repair and refurbishment B. send it to an all-make repair facility adjustments until the PT reports improvement. A. connected the hearing instrument to the manufacture's software and mak D. Tells them that they will not work on hearing aids that are 5 years old - verification. C. return it to the PT and have them complete APHAB When a hearing instrument is returned from repair, the hearing instrument specialist should A. preform an electro acoustical analysis to verify that its performance is at specifications B. call the family and have them just pick it up- you don't need to see the PT

ILE FINAL EXAM PREP 2025/ACTUAL 210 EXAM

QUESTIONS &ANSWERS| 2025 - 2026 |ILE FINAL

EXAM PREP|ALREADY GRADED A+

The PT brings in their 4 year old high end digital signal processing hearing instrument because its not working at all. It is out of warranty. The entire source of the problem has not been found and the hearing instrument is still not working. Atthis point the hearing instrument specialist has no choice but to A. recommend that they purchase a new set D. preform ear measurements on the hearing instrument before the PT arrives to pick it up. - ANS:->>>-- A. preform an electro acoustical analysis to verify that its performance is at specifications A new PT makes an appointment for a repair of their older BTE. There is an accumulation of wax and debris in the tubing. Once the tubing is changed, feedback is eliminated and a sound check indicates that the aid is working nicely. The new PT reports that they need the performance adjusted, they're just not hearing too well. The hearing aid specialist. es ds C. preforms a hearing test, reprograms the instrument, and preforms real-ear B. Has them make a return appointment for an evaluation for new hearing ai

C. increasing the low frequency gain, decreasing the high frequency gain D. decreasing the low frequency gain, decreasing the high frequency gain. - ANSWER-- D. decreasing the low frequency gain, decreasing the high frequency gain. B. decreasing the low frequency gain, increasing the high frequency gain the low frequency gain, increasing the high frequency gain tinny. These can often be addressed by and , respectively A. increasing B. clear out these components and check if the hearing instrument is working C. replace both components in the office D. recommend a medical referral - ANSWER-- B. clear out these components and check if the hearing instrument is working A. send it back for repair hearing aid specalist should If the reciever and or the mircophone is completely plugged with wax or debris, the ANS:->>>-- C. preforms a hearing test, reprograms the instrument, and preforms real-ear verification. common complaints about the quality of the PT own voice are that its echo-y or Feedback can be from A. a bad battery B. a plugged earmold C. an internal source ( internal feedback) or an external source ( external feedback) D. and internal source ( split earmold tubing) or an external source ( internal feedback) - ANS:->>>-- C. an internal source ( internal feedback) or an external source ( external feedback) ALDs can be categorized according to A. those that connect to the hearing instruments and those that connent to cochlear implants B. the type of alerting device that they activate C. whether they are powered by bluetooth or a 2.4 GHz source D. those that help connect the person with hearing loss to other people and those that accommodate an activity of daily living

  • ANS:->>>-- D. those that help connect the person with hearing loss to other people and those that accommodate an activity of daily living

instruments. An example of this is enviroment can be improved in simple ways to benefit a person who wears hearing One aspect of councilibng may be to educated family/friends that the acoustic C. have outcomes measures that show that better situational hearing has been achieved D. All of the above

  • ANSWER-- D. All of the above B. proved evidence of a desired outcome from the wearers perspective A. demonstrate that the PT hearing issues have been resolved When the hearing aid specialist validates the fitting, they
    • ANS:->>>-- A. True and must be combined with speech to optimize audibility and intelligibility A. sign language, signed English B. lipreading, sign language C. visual ques, good communication practices D. captions, speechreading
      • ANS:->>>-- C. visual ques, good communication practices A. when walking away from the person who wears hearing aids just speak louder B. Always to try to have important conversations in a highly reverberant room C. speech is easier to hearing and understand when the room has few smooth, reflective surfaces ( drapes and carpets work well) D. in the car seat the person with the hearing loss next to the window - ANS:-

    -- C. speech is easier to hearing and understand when the room has few smooth, reflective surfaces ( drapes and carpets work well) PT challenges with communication must be fully explored so that they hearing aid specalist can educate amplification candidates about A. gateway devices that will wirelessly connect the wearer with a cell phone, Ipod, tablet, computer or any other bluetooth enabled device B. alerting devices C. telecoils D. all of the above

B. False - ANSWER-- True

  • ANS:->>>-- D. all of the above Another aspect of counseling involves introducing the PT to aural rehabilitation to A. enhance their listening skills through improvements in auditory memory and processing speed B. avoid asking "what or HUH" C. enjoy group social events on a monthly basis D. re-train their brain to eventually do without hearing aids – ANS:->>>-- A. enhance their listening skills through improvements in auditory memory and processing speed FOr the hearing aid specialist to adequately validate the fitting they must first define what the PT desired outcome is for the fitting and then select the appropriate tool to measure it. A. True Self-assessment methods of validation are also referred to as A. objective verification methods B. questionnaires C. subjective methods D. objective Methods
    • ANS:->>>-- C. subjective methods Audiometric methods of hearing instrument fitting validation are sometimes referred to as A. objective/subjective methods B. Soundfield audiometry C. Subjective methods D. Objective methods
  • ANS:->>>-- D. Objective methods The main difference between speech mapping and real ear insertion response verification procedures is

instruments B. ignores all of the real ear data and addresses that cosmetic appeal of the wearer that they'll just have to get used A. returns that settings to where they were when they met all targets and tells B. tell the wearer they will have to accommodate to the hearing instruments different sound C. modify the earmold to meet prescriptive targets since the hearing instruments programming computer is not working D. tell the PT to start saving for new instruments - ANS:->>>-- A. perform real ear verification to compare the results to the most recent data before the repair A new binaural fitting has just been completed. The wearer complains that the hearing instruments sound much too tinny. The hearing aid specialist adjusts the frequency response of the hearing aids and solicits the wearer's impression to find complete listening satisfaction. The speech mapping is repeated but fitting targets are now way off. The hearing aid specialist. to it the C. documents the printed speech mapping results and the wearer's chart notes that the real ear data reflect the PT preferred settings D. ignores the prescriptive targets and preforms soundfield testing - ANS:->>>-- C. documents the printed speech mapping results and the wearer's chart notes that the real ear data reflect the PT preferred settings Soundfield functional gain measurements can be used as a fitting verification measurement A. True B. False - ANS:->>>-- A. True The three most commonly employed self-assessment questionnaire's are the A. APHAB, HHI, and the COSI B. case history, credit history and the SRT C. LTASS, SII, and AII D. All of the above - ANS:->>>-- A. APHAB, HHI, and the COSI The handicap imposed by hearing loss can be measured using the. insight

about pre-fitting self-awareness about the hearing loss can be revealed by the A. a case history; family's participation in all discussion

pressure in the ear canal B. to modify the hearing instrument's high frequency response; to decrease low frequency amplification C. to relieve a feeling of pressure in the ear canal; it has become useless with given the flexibility of hearing instrument programming D. to increase the amount of low frequency gain; to relieve a feeling of pressure in the ear canal - ANSWER-- A. to modify the hearing instruments frequency response to relieve a feeling of pressure in the ear canal nozzle/sound hook. The mold had #13 think tubes , but only #12 tubing is now A PT earmold tubing needed changing because it was so stiff it broke at the sound When selecting a custom earmold style and its acoustic modifications the hearing aid specialist must consider A. a patient comfort and preferences and the audiometric data B. the cost of the amplification system C. cosmetic acceptance D. all the above - ANS:->>>-- A. a patient comfort and preferences and the audiometric data available. the hearing instrument specialist can A. make a return appointment when the #13 tubing comes in B. use the # C. recommend that the PT purchase new earmolds D. use the #12 tubing, verify the fitting using probe microphone measurements, and re-program the hearing instrument as needed. - ANS:->>>-- D. use the # 12 tubing, verify the fitting using probe microphone measurements, and re-program the hearing instrument as needed. Venting has 2 purposes and A. to modify the hearing instruments frequency response to relieve a feeling of The "horn effect" refers to A. low frequency emphasis B. Boyle's law C. a tinny sound quality from too much high frequency emphasis D. a progressive change in diameter of the sound bore that provides high frequency emphasis in the response of the hearing instrument system - ANS:->>>-- D. a

progressive change in diameter of the sound bore that provides high frequency emphasis in the response of the hearing instrument system Earmold or shell modifications can be made in the office to improve the wearer's comfort as well as to alter the frequency response of the hearing instrument system A. true B. false - ANS:->>>-- A. true Silicone is the preferred material for ear impressioning A. True B. False - ANS:->>>-- A. True The bulb on the otoscope has burned out, and a replacement is not immediately available. The hearing care professional should A. use the earlight to inspect the ear canals B. go ahead with the impression anyway since the PT was just at the physician's office 2 weeks ago C. use the audiometric data to determine the likelihood that the ear canals are clear D. none of the above - ANS:->>>-- D. none of the above it is not necessary to bridge and brace when using instruments in the PT ear canal when A. they seem like they can sit very still and not move B. it is always necessary to bridge and brace C. doing otoscopy D. inserting the impression material using a gun - ANS:->>>-- B. it is always necessary to bridge and brace When positioning the otoblock in the ear canal A. shallow placement is adequate for a low gain hearing instrument B. push it right to the center C. it should be within 2 mm of the TM D. it should always be placed beyond the second bend - ANS:->>>-- D. it should always be placed beyond the second bend

D. insistent family members - ANSWER-- A. need, desire, and personal motivation C. willingness to compromise B. budget D. the candidate assess the everyday impact of their hearing on communication and socialization and return for a follow up appointment in 3 to 6 months - ANS:->>>-- D. the candidate assess the everyday impact of their hearing on communication and socialization and return for a follow up appointment in 3 to 6 months To accommodate for slower processing rates of some older adults the hearing care professional and their staff should A. speak at a slower rate B. Speak clearly C. face the PT in a well-lighted room D. all the above - ANS:->>>-- D. all the above The decision to pursue amplification depends on the potential hearing instrument wearer's A. need, desire, and personal motivation its not the degree of a person's hearing loss but the impact of the hearing loss on effective communication and personal relationships that compels an individual to seek a professional hearing consultation A. true B. false - ANS:->>>-- A. true The acoustical environment impacts on hearing clearly primarily due to A. distance from the speaker B. reverberation C. completing noise D. all the above - ANS:->>>-- D. all the above hearing instruments are programmed using software that provides excellent control over their electroacoustic performance. Therefore, audiometric slope or configuration does not need to be considered when making a recommendation for the style of hearing instrument that would best address the listening and

cosmetic concerns of the wearer

D. the bureau of international standards - ANSWER-- A. ISO and IEC C. IES and ISC C. swimming; playing cards D. Challenges hearing at work; hearing at weddings when the band is playing ANSWER-- B. Telephone use; television viewing B. Telephone use; television viewing A. cosmetic appeal; cost Active and consistent use of amplification will enable the full potential and benefits from the hearing instruments A. true B. false - ANS:->>>-- true ANSI stand from A. national standard institute B. American national specifications institute C. acoustical and national standards institute D. American national standards institute - ANS:->>>-- D. American national standards institute ANSI publishes standards for several hearing instrument professional issues, such as audiometric test environment and equipment calibration A. true B. false - ANS:->>>-- true Some countries use for defining national hearing instrument standards A. ISO and IEC B. IETC and CIC A. PTA's and WRS scores B. Cosmetic appeal and cost C. feedback and occlusion D. size of the ear canal and whether the candidate wears eyeglasses - ANSWER-- C. feedback and occlusion accessories must consider and are two lifestyle issues that the recommendations for style and/ or

the ANSI test battery measures the hearing instruments performance of its major

pressure level from the TM to the oval window what is the function of the basilar membrane? - ANS:->>>-- supports the organ of Corti contact with which anatomical feature can cause a cough reflex - ANS:->>>-- branch of vagus nerve which portion of the ear contains sebaceous gland - ANS:->>>-- outer portion of the external portion what is the function of the helicotrema? - ANS:->>>-- connects both the scala tympani and scala vestibuli in order to properly sanitize auditory test equipment, what must be used following cleaning? - ANS:->>>-- low level disinfection A PT complains of a foul smelling fluid coming from the right ear. Otoscopy reveals debris and fluid originating from the superior portion of the TM. What is the likely cause of these symptoms - ANS:->>>-- Cholesteatoma A hearing health care professional is preforming tympanometry on a PT who has a malfunctioning eustachian tube. which type of tympanometry should be anticipated? - ANS:->>>-- C which tests determine the type and degree of hearing loss - ANS:->>>-- air and bone conduction threshold a woman walks through the front door of her split-level house and hears her daughter and a friend talking downstairs in the family room. what allows the woman to discern that her daughter is downstairs instead of upstairs. - ANS:->>>-- auricle and canal resonance a PT is referred by a physician who diagnosed mucoid otitis media the previous day. How will the PT TM likely appear. - ANS:->>>-- opaque and normal the isthmus is located just beyond what anatomical structure? - ANS:->>>-- second

B. battery size, volume control - ANSWER-- A. battery size, auto coil A. battery size, autocoil selecting amplification for a PT who has limited dexterity or coordination? which two characteristics of a hearing instrument should be prioritized when canal bend what impact does the upward spread of masking have on intelligibility? - ANS:->>>-- low frequencies interfere with high frequencies a PT who communicates in different language than the hearing healthcare professional arrives for a hearing evaluation. what test should a hearing healthcare professional include in the evaluation? - ANS:->>>-- SAT What noise is delivered for masking air conduction - ANS:->>>-- Narrow band noise When do you have to mask for air conduction with headphones and inserts

ANS:->>>-- Headphones 40 DB difference and inserts 70 DB difference What noise do you have to deliver for bone conduction - ANS:->>>-- Narrow Band noise When do you have to mask for bone conduction - ANS:->>>-- When there is a 15 DB or greater difference between the air conduction and bone conduction thresholds When there is a 15 DB or greater difference between the air conduction and bone conduction thresholds - ANS:->>>-- Tympanometry type a - ANS:->>>-- Normal Tympanometry type a S - ANS:->>>-- Short or stiff low compliance