Massachusetts Oil Burner Study Guide: Questions and Answers for Technicians, Exams of Petrochemistry

This study guide provides a comprehensive set of questions and answers related to oil burner systems, covering topics such as combustion, safety, installation, and maintenance. It is a valuable resource for technicians seeking to enhance their knowledge and understanding of oil burner systems in massachusetts.

Typology: Exams

2024/2025

Available from 02/10/2025

tizian-kylan
tizian-kylan 🇺🇸

2.7

(21)

3.8K documents

1 / 28

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
Massachusetts Oil Burner Study Guide
Rated A+
What is the voltage found at the TT terminals ✔✔24 volts
What are the 8 steps of a no heat call ✔✔1 talk to customer 2 check tt.3 check to make sure an
emergency switch is on 4check to make sure there is oil in the tank 5 check to make sure the
main power going to the unit is on six check to make sure that tank shut off valve is open 7 know
whether the tank is located above or below the burner I know the type and style of the system
that is being used on a one or two pipe system
What is a cad cell ✔✔A device containing condominium sulfide used to prove the flame in oil
burner furnace
How much air is needed to burn a gallon of number 2 fuel oil and why. ✔✔In 2015 most oil
burners are set up to burn with approximately 50% excess air because it would be dangerous to
set up a burner for exactly the correct amount of air
What is the term InStep mean ✔✔The stack relay is operating correctly
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c

Partial preview of the text

Download Massachusetts Oil Burner Study Guide: Questions and Answers for Technicians and more Exams Petrochemistry in PDF only on Docsity!

Massachusetts Oil Burner Study Guide

Rated A+

What is the voltage found at the TT terminals ✔✔24 volts

What are the 8 steps of a no heat call ✔✔1 talk to customer 2 check tt.3 check to make sure an emergency switch is on 4check to make sure there is oil in the tank 5 check to make sure the main power going to the unit is on six check to make sure that tank shut off valve is open 7 know whether the tank is located above or below the burner I know the type and style of the system that is being used on a one or two pipe system

What is a cad cell ✔✔A device containing condominium sulfide used to prove the flame in oil burner furnace

How much air is needed to burn a gallon of number 2 fuel oil and why. ✔✔In 2015 most oil burners are set up to burn with approximately 50% excess air because it would be dangerous to set up a burner for exactly the correct amount of air

What is the term InStep mean ✔✔The stack relay is operating correctly

What is normal pump pressure ✔✔100 PSI

How is combustion achieved ✔✔Atomization, air, ignition.

What is primary air and secondary air ✔✔Primary air, air that is introduced to a furnace burner before the combustion process has taken place. secondary air, air that is introduced to the furnace after combustion has taken place and that supports combustion

How should an oil tank be supported ✔✔It shall be secured attached to a non-combustible supports

What is the wire gauge use an oil burner circuits ✔✔14 gauge 15 amp fuse

How is an oil burner wired ✔✔Shall be wired on its own circuit. All protective control and emergency devices shall be series connected in the grounded line conductors. all the electrical wiring shall be in accordance with 527 CMR 12.00 Massachusetts electrical code

What size vent pipe is required with a 2 inch fill pipe ✔✔A fill pipe shall not be greater than the vent pipe. The minimum the fill pipe in the state of Massachusetts is one and one quarter inch.

What is the flash point of number 2 fuel oil ✔✔115 degrees Fahrenheit

When does the law require a combustion efficiency test ✔✔During installation and maintenance

What controller shuts off the oil burner in the event of excessive temperature in the appliance ✔✔The high limit switch

What are the three functions of an oil pump ✔✔1- filters 2- pressurizes 3- pumps fuel to the burner

How is an oil burner circuit wired ✔✔In series on its own circuit

How is oil flow adjusted in a rotary burner ✔✔Constant level and metering valve

What does InStep mean ✔✔The stack relay is operating properly

How is combustion achieved ✔✔Atomization ,air ,ignition.

What is the minimum size oil line for residential burners ✔✔3/8 inch

How is safety timing checked on a stack relay switch ✔✔Remove the stack relay from the duck and let it run .it should shut off in 45 seconds.

What is the safety lockout time on Burner firing under 3 gallons per hour ✔✔45 seconds

What control devices are found on gravity feed burners ✔✔Constant level valve

When is a vent pipe required ✔✔When the Supply tank is larger than 10 gallons

What is the time limit for submitting certificate of completion ✔✔Within 72 hours

What kinds of joints are used on tank installations ✔✔Swing joints

Why are swing joints used on oil tank installations ✔✔Shifting with in the tank

When does code require low water cutoff ✔✔Always on a steam boiler ,and when hot water heater has an input rating of 400,000 BTUs an hour or greater

What are the three functions of a pressure regulating valve on an oil pump ✔✔Maintain boiler pressure clean sharp cut off and Supply oil.

What must be done prior to installing an oil burner ✔✔One must get a permit before installing an oil burner

What are the four no heat call steps ✔✔#1Oil check#2 fuse breaker#3 emergency switch# power

What are the requirements for oil fuel vent pipes that terminate outside of the building ✔✔No openings within two feet of vent

What is the safety timing of a gas pilot ignition ✔✔15 seconds or less

What must be done to install an additional fuel tank in a building that already has a tank holding 1320 gallons ✔✔They must have a firewall around them

What must be done with the bypass plug on a two pipe system and on a one pipe system ✔✔On a one pipe system. the bypass plug must be removed .on a two pipe system the bypass must be installed.

What is a bypass plug ✔✔A 1/16 inch plug to convert 1 pipe to a 2 pipe system

What is a power burner ✔✔Anything that's not a vaporizing oil burner

Can a series 10 .3 wire thermostat be used with a 2-wire control? explain. ✔✔Yes by jumping out the ground

Can a series 80 dryer thermostat be wired into a 3-wire control ✔✔No

What is the greatest loss in a boiler ✔✔Heat loss through the chimney

How high on the wall should thermostat be installed ✔✔5 feet from the ground

How much air is needed to burn a gallon of fuel oil and why ✔✔14.4 plus 50% 192 feet cubed 154 CF to ensure enough oxygen

When visually adjusting the flame on an oil burner you should try to get ✔✔An orange flame with red Flame tips

Explain how a burner should be piped when the supply tank is located below the burner ✔✔2. Pipe dual stage with a bypass plug

How should a stack switch be installed according to 527 CMR 4.00 ✔✔With a flexible conduit

Why should a stack switch not be rigidly mounted ✔✔So you can pull it out and check it

What are the purposes of a hot and cold contacts in stack switches ✔✔Hot: as they heat up hot contacts close .Cold: normally closed switches open when heat heats them up.

What is delayed ignition ✔✔Fuel introduced to the combustion chamber before ignition

What are two causes of delayed ignition ✔✔The igniter electrodes or weak Transformer

how is a cad cell primary control relay put in step ✔✔The reset button

On domestic oil tanks when is it necessary to install a vent alarm ✔✔On tanks greater than 10 gallons

Must every fuel tank have a gauge ✔✔No .only on tanks greater than 10 gallons.

What is the Pensky Martens test ✔✔It's a Flashpoint test

List all requirements for the fill and vent pipes ✔✔Swing joints on the fill pipe minimum of one and one-quarter inch and the vent has to be as large or larger than the fill. vent must be two feet away from any opening in the house and it must be three feet off grade

List all the devices necessary for safe operation of a forced hot water system with domestic start from the fuse box ✔✔Fuse box emergency switch thermal cut-out service which limit switch primary control

What is the purpose of a reverse acting control ✔✔To prevent cold water from being circulated on cold start

How is a safety lockout determined on a stack switch without removing it from its holder ✔✔Remove the third terminal

Is CO2 test determines ✔✔The percentage of carbon dioxide in the flue gas

When Shall steam heating boiler and a hot water boiler require inspection by the commissioner of mass Dept of Public Safety before it is put into service ✔✔Any time a permit is pulled to install or alter a burner

Where is the check valve installed on a two pipe system when there is a lift situation ✔✔As close to the tank as possible supply-side

How many seconds must have primary safety control shut off the burner ✔✔Firing Less Than 3 gallons per hour 45 seconds firing 3 - 7 gallons per hour 15 seconds

What is normal pump pressure ✔✔100 PSI

What would be the advantages of a pump pressure higher than 100 PSI ✔✔A cleaner burn

What determines the size of a nozzle gallons per hour ✔✔The maximum firing rate

What is the purpose of a draft regulator ✔✔To get the proper amount of air flow through the burner

What are two ways to adjust draft ✔✔Primary and secondary air ,and the draft regulator

What is the purpose of a flow check valve ✔✔Make sure flow of water does not go into the Zone that's it is unwanted

What is the minimum gauge of an above-ground tank ✔✔12 gauge

What are the two motor speeds ✔✔1725 and 3450

What is a drop lever valve ✔✔Oil shut off

What effect would cut down on excess air have on co2 percentage ✔✔It would increase CO readings

The limit on a steam boiler operates by ✔✔Pressure

What is the approval of a 660 gallon tank ✔✔Standard of UL 80

What is the approval of an oil tank larger than 660 gallons ✔✔Standard of UL 142

Can two supply tanks be provided with only one fill pipe and vent pipe ✔✔Yes

Can Teflon tape be used on oil line connections ✔✔No

When must oil lines be in closed in a non-metallic sleeve ✔✔When there is direct contact with concrete or Earth

What is a gallon of oil ✔✔The amount of oil to occupy one standard u.s. gallon 231 cubic inches at a temperature of 60 degrees Fahrenheit

How should multiple oil tanks be separated from other portions of a building ✔✔2 hour rated fire resistive assemblies with openings protection and continuity

How should a little tank of less than 10 gallons be installed ✔✔At least 2 feet from any heat source

When when installing a tank larger than 10 gallons capacity is provided with an opening in the bottom for use as a burner Supply connection or as a drain how should the tank be pitched ✔✔Towards the opening

What is code with tank insulation inside garages ✔✔Must have a Automotive protective barrier.

Individual Supply tanks larger than 660 gallons shall be enclosed ✔✔True

How should an enclosed tank be supported ✔✔By at least four inches above the floor by Masonry sadels at least 12 inch thick space not more than 8 feet on Center and extending the full

What is the difference between an auxiliary tank and Supply tank ✔✔Supply tank is the primary tank the auxiliary tank is a secondary tank

What is the purpose of Form 1 ✔✔An application for a permit to install or alter oil burning equipment

Can stack switches be used as a primary control ✔✔Yes

How much time do you have to file an application after an emergency install ✔✔24 hours excluding weekends and holidays

According to code when is a low water cut off required on a steam boiler ✔✔Steam boilers and hot water boilers above 400000 BTUs

According to code when is a low water cut off required on a water boiler ✔✔Always

On a no heat call why would the system run when you jump out the T&T terminals ✔✔Bad thermostat or faulty wiring

When are two thermal switches required ✔✔When in a room with 12 foot ceilings are higher

What is considered a good draft ✔✔.01 - .02 inches of water column

The primary control must be capable of reacting to ✔✔The presence or absence of a flame

The heat anticipator in a thermostat should be set to ✔✔The amperage draw of the control unit

Electrical current the amount of electricity flowing in a circuit is measured in ✔✔Amps

Advantage of PSC Motors over conventional split phase Motors is they ✔✔Are protected by an overload switch

Before using an electronic analyzer you must ✔✔Performers smoke test to be sure you're bringing at 0 to trace of smoke

If a oil pumps gears are partially impeded by rust and difficult to turn it can cause ✔✔The amperage draw of the burner motor to increase