Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

MK1 SWE Actual Exam Questions | 100% Correct Answers | Verified 2024 Version, Exams of Motor Vehicle Design

what are two types of maintenance - ✔✔Corrective and preventative What article always captain to conduct NJP - ✔✔Article 15 Where two types of procedures that may be accessed from maintenance procedure option - ✔✔Official and local Who is authorized to conduct tag outs - ✔✔Authorizing officer Out of calibration tags should be used when - ✔✔When indicating parameter errors are small and consistent For modernized units the boat inspection reports are to be entered through - ✔✔Almis/ EALpage Cutter engineering report shall be completed in accordance with - ✔✔Naval engineering manual chapter 90 On an MPC the warning shall come where in the text - ✔✔Before the instruction On an MPC what would constitute an expendable - ✔✔Rags PMS that does not need to be included in the cutter engineering

Typology: Exams

2023/2024

Available from 08/30/2024

tizian-kylan
tizian-kylan 🇺🇸

2.7

(21)

3.7K documents

1 / 13

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
MK1 SWE Actual Exam Questions | 100%
Correct Answers | Verified 2024 Version
what are two types of maintenance - ✔✔Corrective and preventative
What article always captain to conduct NJP - ✔✔Article 15
Where two types of procedures that may be accessed from maintenance procedure option - ✔✔Official
and local
Who is authorized to conduct tag outs - ✔✔Authorizing officer
Out of calibration tags should be used when - ✔✔When indicating parameter errors are small and
consistent
For modernized units the boat inspection reports are to be entered through - ✔✔Almis/ EALpage
Cutter engineering report shall be completed in accordance with - ✔✔Naval engineering manual chapter
90
On an MPC the warning shall come where in the text - ✔✔Before the instruction
On an MPC what would constitute an expendable - ✔✔Rags
PMS that does not need to be included in the cutter engineering report is - ✔✔Daily and weekly
With regards to casreps what is mandatory on all updates corrects and cancellations - ✔✔REF
Which unit besides a shore unit are exempt from filling out the POSIT line - ✔✔Cutter underway
pf3
pf4
pf5
pf8
pf9
pfa
pfd

Partial preview of the text

Download MK1 SWE Actual Exam Questions | 100% Correct Answers | Verified 2024 Version and more Exams Motor Vehicle Design in PDF only on Docsity!

MK1 SWE Actual Exam Questions | 100%

Correct Answers | Verified 2024 Version

what are two types of maintenance - ✔✔Corrective and preventative What article always captain to conduct NJP - ✔✔Article 15 Where two types of procedures that may be accessed from maintenance procedure option - ✔✔Official and local Who is authorized to conduct tag outs - ✔✔Authorizing officer Out of calibration tags should be used when - ✔✔When indicating parameter errors are small and consistent For modernized units the boat inspection reports are to be entered through - ✔✔Almis/ EALpage Cutter engineering report shall be completed in accordance with - ✔✔Naval engineering manual chapter 90 On an MPC the warning shall come where in the text - ✔✔Before the instruction On an MPC what would constitute an expendable - ✔✔Rags PMS that does not need to be included in the cutter engineering report is - ✔✔Daily and weekly With regards to casreps what is mandatory on all updates corrects and cancellations - ✔✔REF Which unit besides a shore unit are exempt from filling out the POSIT line - ✔✔Cutter underway

A casrep it should be made as soon as possible no later than ____hours - ✔✔ 24 Casualties that effect a secondary mission should always have a casualty category of - ✔✔ 2 AMPN is mandatory after any set that contains an entry of? - ✔✔Other, tech, none In a 1PARTSID if the NIIN is not known what needs to be put in the line - ✔✔Unknown What is the criteria for submitting CASCOR - ✔✔The delay expressed an hours, and correcting the casualty due to parts unavailability, a list of all parts requested and dates received; the total number of man-hours expanded; the number of equipment hours since last failure You find something else wrong with the piece of equipment that has already been CASREP'd you should send an? - ✔✔Update Where do you find the hierarchy of guidance for specification plans - ✔✔NEM chapter 41 Which specifications may be used as a guided researching propose engineering changes and solutions - ✔✔GSO Which specification do not apply to construction, alteration or maintenance of Coast Guard cutters - ✔✔Commercial general specifications for t-ships Where do you find the authorized material list for deck coverings - ✔✔Naval engineering manual chapter 634 110 - WPB - 521 - 01, what does 5 21 represent - ✔✔SW BS number

Installed in all PIM1 and PIM2 cards - ✔✔MPU What does CAN mean in a CAN buss - ✔✔Controller area network What is the first thing you should do when the remote operating station for an MTU engine has no lights and no alarms - ✔✔Check voltage How long will a wet cell battery go for off a charger for it needs to be recharged - ✔✔4 to 6 months When using a ammeter to troubleshoot always use the____ scale - ✔✔Highest With the float charge the charger monitors what - ✔✔Voltage In a wet cell battery what should the electrolyte level be - ✔✔3/ In a gel cell battery what is the purpose of the separating plates - ✔✔Separates the positive and negative cells preventing short circuiting A WG of a wire is measured by - ✔✔The bare wire in the opening of the gauge Amperage of the wire is measured in reference to - ✔✔10 and 100 foot lengths The standard for wire Manufacturing is - ✔✔American wire gauge The color of the wire is used to determine the _____ of the wire - ✔✔Size Conductivity of jacket water shall not exceed - ✔✔150 mohms /cm

Jacket water is tested - ✔✔Monthly How often do you zincs last - ✔✔Three months When is a zinc not required - ✔✔Exclusive freshwater boats A thrust bearing supports what type of movement - ✔✔Axial With regards to flange shielding on the diesel fuel system what is considered a hot surface - ✔✔ 400 ° What is a hose shelflife - ✔✔10 years Rudder stock is supported by what - ✔✔Bearing If you have a bearing failure in a centrifugal pump with excessive vibration what is the likely cause - ✔✔Misalignment What is disadvantage every centrifugal pump - ✔✔Suction lift RO dumps overboard at what parts per million - ✔✔500 ppm And a RO the pressure needs to be at least - ✔✔350 psi How does a rise in RO input water temperature affect the output rate - ✔✔Increases What is one eighth of a decimal - ✔✔. How many digits an NSN - ✔✔ 13

What is the time limit for resetting the ECM on a Honda 225 - ✔✔20 seconds What rpm does the Honda drop to when there is a loss of oil pressure alarm - ✔✔1800 RPM What is the acceptable leakage rate for the screw type hydraulic pump shaft seal - ✔✔50 mL What percentage hydraulic failure is due to contamination - ✔✔80% What is the smallest size micron particle that can be seen with the naked eye - ✔✔40 micron What happens hydraulic oil for every 18° temperature rise above 40° - ✔✔Oxidation rate doubles What is used to measure the efficiency of the filter - ✔✔Beta ratio Which component can be pressure compensated or non pressure compensated - ✔✔Flow control valve What does a preheater and HVAC system do - ✔✔Heat intake air preventing condensation Refrigeration works on the principle of - ✔✔Heat moves to cold The greater the temp difference - ✔✔The faster the heat transfer What type of engine is a P100 - ✔✔Single cylinder four stroke diesel What type of fuel is used in the P100 - ✔✔JP5 and f How long can you store a dry cell battery proper condition - ✔✔Two years

What is AMPN info mandatory - ✔✔Recording delay in correcting casualty due to parts unavailability number of hours expended correcting casualty and number of operating hours since last failure Who causes aeration in the hydraulic system if there are no leaks - ✔✔Low fluid What are the four center positions of the DCV - ✔✔Open closed tandem floating Approximate how long will it P6 pump run on a tank of fuel - ✔✔4 hours A potable water hose should be labeled every - ✔✔10 feet The ____ permits compressor starting at reduce load - ✔✔Unloader What are the four parts of a turbine - ✔✔Compressor combustor turbine auxiliary What is the most common cause of failure in a piston rotary actuator - ✔✔Metal to metal contact If you find 40 psi in tanB trailer tire what type of discrepancy - ✔✔Restrictive What is a hose shelflife - ✔✔10 years When is it cutter engineering report do - ✔✔January 31 Zone type HVAC system where will 1 duct go - ✔✔Several spaces What are two types of gate valves - ✔✔Parallel and wedge

Honda 225 uses 87% octane and 10% ethanol - ✔✔... What fuel has D icing inhibitors - ✔✔JP five and F 44 Any modernized unit what do you check to see if the asset is safe to operate - ✔✔The condition What is the size of the Safety chain on the trailer - ✔✔Half inch E4 in the Air Force - ✔✔Senior airman 03 in the Air Force - ✔✔Capt. 09 in the Marines - ✔✔Lieut. Gen. E8 in the Marines - ✔✔Master Sgt. You find something else wrong with a piece of equipment already CASREP that you should send a blank - ✔✔Update Which component can be pressure compensated or non-pressure compensated - ✔✔Flow control valve How is TI and measured in a spectrometric oil analysis - ✔✔Parts per million Vacuum gauges indicate and what - ✔✔HG Rudder stock is supported by what - ✔✔Bearings

What is the acceptable leakage rate for screwed tight hydraulic pump shaft seal - ✔✔50 mL As wire size increases what happens to resistance and amperage - ✔✔Resistance down amperage up What percentage of working pressure do you tested temporary hose to - ✔✔150% What coolant is used in a keel cooler - ✔✔Anti-freeze At a modernized unit where is your boat inspection report recorded - ✔✔Almis How many digits are in an NSN - ✔✔ 13 What percent hydraulic failure is due to contamination - ✔✔80% When using an ammeter to troubleshoot a system always use the _____ amp - ✔✔Highest The most common type of media for course filtration is - ✔✔Surface media What is the max time for E M I - ✔✔Two hours The MPU - 23 card exhibits what color lights on the panel when operating normally - ✔✔Green yellow yellow How would you test a 4-20ma sensor - ✔✔In series PMS it does not need to be included in the cutter engineering report is - ✔✔Daily and weekly A.m. p.m. is mandatory after any set that contains an entry of - ✔✔Other tech none

What does article 31 allow - ✔✔The right to remain silent What is article 91 - ✔✔Failure to obey a direct order