Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

NICET Level 1 Fire Alarms: Questions and Answers (2025/2026 Update), Quizzes of Safety and Fire Engineering

A collection of questions and answers related to nicet level 1 fire alarms, covering topics such as smoke detectors, heat detectors, pull stations, visual notification, and nfpa 72 standards. It is a valuable resource for individuals preparing for the nicet level 1 fire alarm certification exam.

Typology: Quizzes

2024/2025

Available from 02/18/2025

tizian-kylan
tizian-kylan 🇺🇸

2.7

(21)

3.8K documents

1 / 16

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1
NICET
NICET Level 1
NICET LEVEL 1 FIRE ALARMS (2025/ 2026
UPDATE) QS & AS| 100% CORRECT| GRADE A
(VERIFIED ANSWERS)
The Digital Alarm Communicator Transmitter is always located at: - ANS
the protected premises
An EOL device is always placed at the end of __________ for maintaining
supervision. - ANS a class B circuit
The Fire Alarm Control Panel should not be configured to supply power to
detection devices. - ANS FALSE. The fire alarm control panel may supply
power to the detection devices. It may be a local unit or master control unit.
What ratings indicate in hours the ability of a structure to withstand fire? -
ANS FIRE RATINGS
Codes are the minimums that must be complied with. True? - ANS TRUE.
Codes are the minimums that must be complied with.
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download NICET Level 1 Fire Alarms: Questions and Answers (2025/2026 Update) and more Quizzes Safety and Fire Engineering in PDF only on Docsity!

NICET

NICET LEVEL 1 FIRE ALARMS (202 5 / 2026

UPDATE) QS & AS| 100% CORRECT| GRADE A

(VERIFIED ANSWERS)

The Digital Alarm Communicator Transmitter is always located at: - ANS ✓the protected premises An EOL device is always placed at the end of __________ for maintaining supervision. - ANS ✓a class B circuit The Fire Alarm Control Panel should not be configured to supply power to detection devices. - ANS ✓FALSE. The fire alarm control panel may supply power to the detection devices. It may be a local unit or master control unit. What ratings indicate in hours the ability of a structure to withstand fire? - ANS ✓FIRE RATINGS Codes are the minimums that must be complied with. True? - ANS ✓TRUE. Codes are the minimums that must be complied with.

NICET

Which standard explains how a fire alarm system should be installed? - ANS ✓NFPA 72 When you install smoke detectors on the ceiling, no portion of these detectors should be placed within _____ of any sidewall. - ANS ✓smoke detector shall not be installed within 4" of any sidewall Smoke detectors are only required in residential buildings with a gross area of 20,000+ square feet. - ANS ✓FALSE. Smoke detectors are required in all residential buildings. Residential occupancies should be equipped with at least how many smoke detectors on each floor? - ANS ✓AT LEAST ONE (1) SMOKE DETECTOR PER FLOOR You need to perform notification voltage drop calculations in order to determine: - ANS ✓if the power at the last notification device is strong enough Talking about visual notification, when multiple strobes are in the field of vision: - ANS ✓these strobes MUST be synchronized in their flashing

NICET

Talking about visual notification, wall mount strobes must be mounted between _____ and _____ inches from the floor level. - ANS ✓18.5.5.1* 80 and 96 inches from the floor level When you install smoke detectors on a wall, no portion of these detectors should be installed within _____ of the ceiling - ANS ✓17.7.5.6.5.1 smoke detectors on a wall should be installed within 4" of the ceiling A fire alarm systems secondary power source must not be implemented through using battery backup. - ANS ✓FALSE. A fire alarm systems secondary power source may be implemented through using battery backup. What refers to the minimum sound level which a tone signal can become audible in ambient noise? - ANS ✓3.3.82 Effective Masked Threshold - minimum sound level at which the tone signal is audible in ambient noise An auxiliary box is a fire alarm box that must be operated locally. - ANS ✓FALSE. An Auxiliary Box is a fire alarm box that can be operated from a remote initiating device only. The major purpose of annunciation is to: - ANS ✓allow responding personnel to quickly identify the location of the fire

NICET

What is the primary purpose of automatic trouble resound? - ANS ✓to remind the building owners The max room area that may be covered by a ceiling mounted strobe should be no more than: - ANS ✓50 feet x 50 feet, single ceiling mounted strobe A Master Box is publicly accessible. - ANS ✓TRUE. It may also be operated by a remote initiating device. You can verify the operability of all your controlled mechanical equipment through: - ANS ✓periodic testing Building codes usually call for the installation of voice evacuation systems: - ANS ✓TRUE 17.14.8.3* Manual pull stations are required to be red in color. - ANS ✓TRUE Ion detectors can detect a flaming fire faster. - ANS ✓TRUE; flaming fire (not smoldering)

NICET

Fixed temperature spot-type detectors are most suitable for: 3.3.66.7* - ANS ✓enclosed areas A four-wire smoke detector has how many distinct circuits? - ANS ✓two (2) With a four-wire smoke detector, it is the _____ circuit that provides resettable power. - ANS ✓first circuit An initiating device originates transmission in a change of state condition. - ANS ✓TRUE A line type detector can perform detection which is: - ANS ✓continuous along a path Level ceilings have a slope of less than _____ per foot. - ANS ✓1.5 or 1 1/2" inches per foot It is the NFPA 72 that specifies what type of equipment should be used. - ANS ✓FALSE

NICET

In codes, the word __________ often indicates a mandatory equipment. - ANS ✓shall What determines the fire alarm requirements? - ANS ✓locally enforced building code Most codes determine the fire alarm sprinkler requirements base on: - ANS ✓occupancy classification of the involved building In a conventional fire alarm system, it is the number of initiating zones that defines how large the system can be. - ANS ✓TRUE How does a dry contact device work? - ANS ✓dry contacts will close causing an alarm; usually used on conventional systems (zone 1, zone 2) Which of the following are dry devices? pull stations, heat detectors, four- wire smoke detectors, flow switches - ANS ✓all; pull stations, heat detectors, four-wire smoke detectors, flow switches Powered devices must be listed for compatibility. - ANS ✓TRUE, they use voltage from the control panel

NICET

Flashing strobes are always listed for a particular orientation only: - ANS ✓TRUE Spacing requirements for visual devices are based on: - ANS ✓NFPA 72 The largest room area that may be covered by a single wall mounted device is no larger than _____ feet by _____ feet. - ANS ✓NOT SURE A Type _____ Public Fire Alarm Reporting System can retransmit alarms to fire stations manually or automatically. - ANS ✓Type A (A for automatic) 3.3.8 What is an Addressable Device? - ANS ✓It is a fire alarm system component that possesses discreet identification. __________ Detector has a piping distribution network to the areas being protected. Air Sampling-Type detector uses a fan inside its housing to draw air. - ANS ✓3.3.66.1 Air sampling-type An _________ that transmits a signal indicating varying degrees of condition - ANS ✓3.3.132.1 Analog Initiating Device

NICET

A __________ can transmit a signal that indicates on off condition only. - ANS ✓3.3.132.1 Conventional Initiating Device __________ is a feature that can reduce unwanted alarms. - ANS ✓3.3.16 Alarm verification Fire alarms from an auxiliary system are always received at: - ANS ✓Fire alarms from an auxiliary system are always received at the public fire service communication center. Auxiliary Fire Alarm System is connected to: - ANS ✓Auxiliary Fire Alarm System is connected to a municipal fire alarm system. Municipal fire alarm system - ANS ✓A public emergency alarm reporting system Auxiliary Fire Alarm System - ANS ✓A protected premises fire alarm system or other emergency system at the protected premises and the system used to connected the protected premises system to a public emergency alarm reporting system for transmitting an alarm to the communications center.

NICET

Equipment is LISTED - ANS ✓The equipment is included in a list publish by an organization which is acceptable to the "AHJ" With a "non-restorable" initiating device: - ANS ✓the sensing element will be DESTROYED during the process of operation What is a pull station? - ANS ✓PULL STATION is a manually operated device which may be used to initiate an alarm signal. Describe NRTL: - ANS ✓It is the Nationally Recognized Testing Laboratory that is recognized by the OSHA as meeting the qualifications specified in the Code of Federal Regulations. CODE - ANS ✓Code are written rules that are adopted as law. What give the details on how the requirement of the code may be achieved?

  • ANS ✓STANDARDS give the details on how the requirement of the code may be achieved. NFPA 72 recommends that the coverage area for a single zone should not exceed __________ square feet. - ANS ✓20,000 square feet

NICET

NFPA 72 recommends that the coverage area for a single zone should not extend beyond a floor of a building. - ANS ✓TRUE At the max you can have _____ waterflow switches and _____ supervisory switches connected to a single zone. - ANS ✓At the max you can have 5 waterflow switches and 20 supervisory switches connected to a single zone. When you place smoke and heat detector on a peaked ceiling, you should measure _____ feet horizontally from the peak in both directions. - ANS ✓When you place smoke and heat detector on a peaked ceiling, you should measure 3 feet horizontally from the peak in both directions. When you install smoke detectors under raised floors: - ANS ✓the detectors SHOULD be mounted in an orientation in which they are listed. Smoke detectors should be installed only after construction clean-up. There is no exception at all. - ANS ✓FALSE. Smoke detectors should be installed only after construction clean-up EXCEPT for protection during construction. The exact requirements for the location of pull stations within a building are dictated by: - ANS ✓BUILDING CODE

NICET

Communicator Receiver can accept and display signals sent from the digital alarm communicator transmitters over the public switched telephone network. An EOL relay device can supervise power for: - ANS ✓An EOL relay device can supervise power for 4-wire smoke detectors.