dated 6 Jun 2013
Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is governed by the terms set out within this report.
Laboratory: TÜV SÜD PSB Pte. Ltd. No.1 Science Park Drive Singapore 118221
Phone : +65-6885 1333 Fax : +65-6776 8670 E-mail: testing@tuv-sud-psb.sg www.tuv-sud-psb.sg Co. Reg : 199002667R
Regional Head Office: TÜV SÜD Asia Pacific Pte. Ltd. 3 Science Park Drive, #04-01/ The Franklin, Singapore 118223
Subject:
Determination of Surface Burning Characteristics of fibre cement boards submitted by Everest Industries Limited
Tested For:
Everest Industries Limited The Genesis, A- Mohan Cooperative Industrial Estate Mathura Road New Delhi 110048 India
Attn: Mr Subrata Dutta
Test Specifications:
ASTM E84-12b “Standard Test Method for Surface Burning Characteristics of Building Materials”
Sample Description:
1- 3 pieces of fibre cement boards ‘Everest Board’ of size 2440mm long x 520mm wide x18mm thick 2- 3 pieces of fibre cement boards ‘Everest Heavy Duty Board’ of size 2440mm long x 520mm wide x15mm thick were received for Surface Burning Characteristics test.
Test Date:
10 May 2013
Test Details:
Test Chamber : Steiner Tunnel Test Location : Japan Electric Cable Technology Center, Inc (Japan) Test Engineers : Mr Toyokazu Horibata & Mr Shigeyuki Hayashi
dated 6 Jun 2013
Test Conditions:
Test Parameters Test Results Requirement Room Temperature (°C) 24.0 23 ± 2. Relative Humidity (%) 49.9 50 ± 5 Starting Temperature at 13ft (floor) (°C) 41.3 40.5 ± 2. Velocity in the furnace (ft/min) 241.9 240 ± 5
Flame Spread Results:
Flame Spread Index (FSI) : 0
Maximum Flame Spread (ft) : 0
Time to ignition (sec) : no ignition
Smoke Results:
Smoke Developed Index (SDI): 0
dated 6 Jun 2013