Test Report No 7191058018-MEC13/03-ED
dated 6 Jun 2013
Note: This report is issued subject to the Testing and Certification Regulations of the T ÜV SÜD
Group and the
General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is governed by the
terms set out within thi s report.
Laboratory:
TÜV SÜD PSB Pte. Ltd.
No.1 Science Park Drive
Singapore 118221
Phone : +65
-
6885 1333
Fax : +65-6776 8670
E-mail: testing@tuv-sud-psb.s g
www.tuv-sud-psb.sg
Co. Reg : 199002667R
Regional Head Office:
TÜV SÜD Asia Pacific Pte. Ltd.
3 Science Park Drive, #04-01/ 05
The Franklin, Singapore 118 223 Page 1 of 10
Subject:
Determination of Surface Burning Characteristics of fibre cement boards submitted by
Everest Industries Limited
Tested For:
Everest Industries Limited
The Genesis, A-32
Mohan Cooperative Industrial Estate
Mathura Road
New Delhi 110048
India
Attn: Mr Subrata Dutta
Test Specifications:
ASTM E84-12b “Standard Test Method for Surface Burning Characteristics of Building Materials”
Sample Description:
1- 3 pieces of fibre cement boards ‘Everest Board’ of size 2440mm long x 520mm wide x18mm thick
2- 3 pieces of fibre cement boards ‘Everest Heavy Duty Board’ of size 2440mm long x 520mm wide
x15mm thick were received for Surface Burning Characteristics test.
Test Date:
10 May 2013
Test Details:
Test Chamber : Steiner Tunnel
Test Location : Japan Electric Cable Technology Center, Inc (Japan)
Test Engineers : Mr Toyokazu Horibata & Mr Shigeyuki Hayashi
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download project for payroll system and more Papers Introduction to Robotics in PDF only on Docsity!

dated 6 Jun 2013

Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is governed by the terms set out within this report.

Laboratory: TÜV SÜD PSB Pte. Ltd. No.1 Science Park Drive Singapore 118221

Phone : +65-6885 1333 Fax : +65-6776 8670 E-mail: testing@tuv-sud-psb.sg www.tuv-sud-psb.sg Co. Reg : 199002667R

Regional Head Office: TÜV SÜD Asia Pacific Pte. Ltd. 3 Science Park Drive, #04-01/ The Franklin, Singapore 118223

Subject:

Determination of Surface Burning Characteristics of fibre cement boards submitted by Everest Industries Limited

Tested For:

Everest Industries Limited The Genesis, A- Mohan Cooperative Industrial Estate Mathura Road New Delhi 110048 India

Attn: Mr Subrata Dutta

Test Specifications:

ASTM E84-12b “Standard Test Method for Surface Burning Characteristics of Building Materials”

Sample Description:

1- 3 pieces of fibre cement boards ‘Everest Board’ of size 2440mm long x 520mm wide x18mm thick 2- 3 pieces of fibre cement boards ‘Everest Heavy Duty Board’ of size 2440mm long x 520mm wide x15mm thick were received for Surface Burning Characteristics test.

Test Date:

10 May 2013

Test Details:

Test Chamber : Steiner Tunnel Test Location : Japan Electric Cable Technology Center, Inc (Japan) Test Engineers : Mr Toyokazu Horibata & Mr Shigeyuki Hayashi

dated 6 Jun 2013

Test Sample : Fibre Cement Board, Everest Board

Test Conditions:

Test Parameters Test Results Requirement Room Temperature (°C) 24.0 23 ± 2. Relative Humidity (%) 49.9 50 ± 5 Starting Temperature at 13ft (floor) (°C) 41.3 40.5 ± 2. Velocity in the furnace (ft/min) 241.9 240 ± 5

Flame Spread Results:

Flame Spread Index (FSI) : 0

Maximum Flame Spread (ft) : 0

Time to ignition (sec) : no ignition

Smoke Results:

Smoke Developed Index (SDI): 0

dated 6 Jun 2013

Photographs (Fibre Cement board, Everest Board)

dated 6 Jun 2013

Photographs (Fibre Cement board, Everest Board)

dated 6 Jun 2013

Fibre Cement Board, Everest Heavy Duty Board

dated 6 Jun 2013

Photographs (Fibre Cement board, Everest Heavy Duty Board)

dated 6 Jun 2013

Please note that this Report is issued under the following terms :

  1. This report applies to the sample of the specific product/equipment given at the time of its testing/calibration. The results are not used to indicate or imply that they are applicable to other similar items. In addition, such results must not be used to indicate or imply that TÜV SÜD PSB approves, recommends or endorses the manufacturer, supplier or user of such product/equipment, or that TÜV SÜD PSB in any way “guarantees” the later performance of the product/equipment. Unless otherwise stated in this report, no tests were conducted to determine long term effects of using the specific product/equipment.
  2. The sample/s mentioned in this report is/are submitted/supplied/manufactured by the Client. TÜV SÜD PSB therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture, consignment or any information supplied.
  3. Nothing in this report shall be interpreted to mean that TÜV SÜD PSB has verified or ascertained any endorsement or marks from any other testing authority or bodies that may be found on that sample.
  4. This report shall not be reproduced wholly or in parts and no reference shall be made by the Client to TÜV SÜD PSB or to the report or results furnished by TÜV SÜD PSB in any advertisements or sales promotion.
  5. Unless otherwise stated, the tests were carried out in TÜV SÜD PSB Pte Ltd, No.1 Science Park Drive Singapore 118221.

July 2011