A comprehensive set of questions and answers related to the rhode island journeyman and master plumber exams. It covers essential topics such as waste stack dimensions, backflow prevention, grease trap sizing, water pipe burial depths, vent clearances, and hot water temperature regulations. The material is designed to help plumbing professionals prepare for certification exams by testing their knowledge of plumbing codes, regulations, and best practices. It includes questions on air tests, water hammer arrestors, copper tubing support, and specific requirements for various plumbing installations, offering a valuable resource for exam preparation and professional development. Useful for those seeking to enhance their understanding of plumbing standards and practices in rhode island. (400 characters)
Typology: Exams
1 / 19
This page cannot be seen from the preview
Don't miss anything!
What is the minimum and maximum length of a waste stack to a trap weir? ---------CORRECT ANSWER-----------------18" and 42" What must be installed before connecting and irrigation system to a potable water supply? ---------CORRECT ANSWER-----------------A pressure reducing backflow preventer Can combustible liquids that condense be allowed down the public sewer? ---------CORRECT ANSWER-----------------Always follow the manufacturers instructions How should a grease trap be sized when hooking it up to a commercial food waste grinder? ---------CORRECT ANSWER-----------------It should be sized to the outlet of the food waste grinder Water pipe should be buried ____________ feet underground. --------- CORRECT ANSWER-----------------4.5' underground A vent which extrudes out the side of a building should be at least _______ and ______ away from doors and windows. ---------CORRECT ANSWER--- --------------10' and 2'
In RI hot water is _________ degrees. ---------CORRECT ANSWER---------- -------110 Degrees There should be a clearance of _________ inches in front of a water closet. ---------CORRECT ANSWER-----------------21" A vent size should be determined by its ________________? --------- CORRECT ANSWER-----------------Length A vent from a bed-pan washer is __________ from being connected to a local vent. ---------CORRECT ANSWER-----------------Prohibited A backwater valve can be buried? ---------CORRECT ANSWER----------------
Unobstructed vertical distance through the free atmosphere between the outlet of the waste pipe and the flood level rim of the receptacle into which the waste pipe is discharging. ---------CORRECT ANSWER-----------------Air Gap Bored, Dug and Driven are examples of what? ---------CORRECT ANSWER-----------------Well The vertical distance from the fixture outlet to the trap weir shall not exceed ________________ and the horizontal distance shall not exceed _______________ measured from the centerline of the fixture outlet to the centerline of the inlet of the trap. ---------CORRECT ANSWER----------------- 24" and 30" How much of a vertical wall should be added to the square footage calculation of a roof? ---------CORRECT ANSWER-----------------Half the square footage of the vertical wall What is the clearance for rodding of a 6" pipe and an 8" pipe? --------- CORRECT ANSWER-----------------18" and 36" respectively A vent must connect _______________ the centerline of a waste line. ------ ---CORRECT ANSWER-----------------Above
What is a branch vent? ---------CORRECT ANSWER-----------------A vent connecting one or more individual vents with a vent stack or stack vent. What is the pressure in pounds at the base of a stack 82' high? --------- CORRECT ANSWER-----------------.434 * 82 = 35.59 psi How many gallons of water are in a tank that is 24" round and 60" high? ---- -----CORRECT ANSWER-----------------24" * 24" * .0034 * 60 = 117. Backfilling, loose earth free from rocks, broken concrete and frozen chunks shall be placed in the trench in ___________ layers and tamped in place until the crown of the pipe is covered by _______________ of tamped earth. ---------CORRECT ANSWER-----------------6" and 12" Where rock is encountered in trenching, the rock shall be removed to a minimum of ____________ below the installation level of the bottom of the pipe. ---------CORRECT ANSWER-----------------3" How many feet of 3/4 copper tubing does it take to hold 1 gallon of water? - --------CORRECT ANSWER-----------------X=1/(.0408x.5625) X=1/. X=43.57' How many roof drains are required on a roof under 10,000 square feet? ---- -----CORRECT ANSWER----------------- 2
Water Services Shall Be Installed Not Less Than: ---------CORRECT ANSWER-----------------4' 6" Below Grade Piping installed in exterior walls or areas subject to freezing must: --------- CORRECT ANSWER-----------------Insulated/Heated or Both Building Sewers connected to a public sewer shall have a minimum coverage of: ---------CORRECT ANSWER-----------------36" Below Grade A safe waste pan shall be installed ---------CORRECT ANSWER--------------- --Under a water heater 6 gallons or greater that is elevated A safe waste pan shall be at least ---------CORRECT ANSWER----------------
Where frost closure is common an increase in vent size shall take place: --- ------CORRECT ANSWER-----------------6"below the roof with an approved fitting High Hazard flood zone is: ---------CORRECT ANSWER-----------------"V" zone (subject to wave heights in excess of 3') Lead free pipe and fittings contain less than: ---------CORRECT ANSWER-- ---------------8.0% Lead Hot water is water at temperature greater than or equal to: --------- CORRECT ANSWER-----------------110 degrees Lead free solder and flux contain no more than ---------CORRECT ANSWER-----------------0.2% Lead Strainer plates on drain lines for rodent proofing must have openings: ------- --CORRECT ANSWER-----------------0.5 inches Sleeves for pipes passing through foundation walls or under footings shall be: ---------CORRECT ANSWER-----------------Two pipe size greater than the pipe passing through it
Sheet lead shall not weigh less than: ---------CORRECT ANSWER------------ -----4 pounds per square foot Sheet copper shall not weigh less than: ---------CORRECT ANSWER--------- --------12 ounces per square foot Urinals shall not be substituted for more than what percent of water closets? ---------CORRECT ANSWER-----------------67% Shower and Tub/Shower valves maximum hot water setting is: --------- CORRECT ANSWER-----------------120 degrees Maximum water temperature of a tankless heater or domestic hot water heater is: ---------CORRECT ANSWER-----------------140 degrees Maximum setting of a temperature pressure and relief valve or a combination thereof is: ---------CORRECT ANSWER----------------- 210 degrees 150 psi Minimum working pressure of a domestic water service either outside or buried is: ---------CORRECT ANSWER-----------------160 psi All hot water distribution piping and tubing shall have a minimum pressure rating of: ---------CORRECT ANSWER-----------------100 psi @180 degrees
Disinfection of the potable water system uses: ---------CORRECT ANSWER-----------------50 parts per million of chlorine for 24 hours The discharge from a reverse osmosis system enters the drainage system through: ---------CORRECT ANSWER-----------------Air gap or air gap device Sanitary sewer and storm drains for the same property can be installed: ---- -----CORRECT ANSWER-----------------Side by side in the same trench Molten lead should be poured in one operation to a depth of: --------- CORRECT ANSWER-----------------Not less than 1" A lead pour when caulked shall not recede ---------CORRECT ANSWER----- ------------0.125 inches Cleanouts for horizontal drains and building sewers 6" and smaller shall be located every: ---------CORRECT ANSWER-----------------100 Feet Building sewers 8" and larger manholes must be installed every: --------- CORRECT ANSWER-----------------400' Each fixture trap shall have a trap seal of not less than: ---------CORRECT ANSWER-----------------2"
When rock is encountered in trenching rock will be removed to a minimum of: ---------CORRECT ANSWER-----------------3" below the installation level Hanger spacing for ABS pipe is: ---------CORRECT ANSWER----------------- 4' Water testing of a drainage system requires a: ---------CORRECT ANSWER-----------------10' head Sizing of storm drains for Rhode Island is based on: ---------CORRECT ANSWER-----------------2.6 inches of rain per hour The Board of Appeals consists of how many members? ---------CORRECT ANSWER----------------- 5 Tempered water is water having a temperature range of: ---------CORRECT ANSWER-----------------85 degrees to 110 degrees A casing is not required with what type of well? ---------CORRECT ANSWER-----------------Driven Backflow for an automatic clothes washer is prevented by: --------- CORRECT ANSWER-----------------Integrally installed air gap or backflow preventer
Waste from an automatic clothes washer discharges through an --------- CORRECT ANSWER-----------------Air Break Water connection to a bidet protected by an ---------CORRECT ANSWER--- --------------Air Gap or Backflow Preventer Water connection to a dishwasher is protected by an ---------CORRECT ANSWER-----------------Air Gap or Backflow Preventer Roof drains shall have strainers extending above the roof a minimum of: --- ------CORRECT ANSWER-----------------4" Separate toilet facilities are not required when ---------CORRECT ANSWER-----------------There are 15 or less employees Minimum pitch for 2 1/2" piping and smaller is: ---------CORRECT ANSWER-----------------1/4" Minimum size wet vent piping is: ---------CORRECT ANSWER----------------- 1 1/2" What is the minimum supply tube to a one-piece toilet? ---------CORRECT ANSWER-----------------1/2" OD
Length (feet) = ---------CORRECT ANSWER-----------------Capacity / .0408 x diameter (feet) squared Capacity (gallons) = ---------CORRECT ANSWER-----------------.0408 x diameter (inches) squared x L (feet) Capacity (gallons) = ---------CORRECT ANSWER-----------------.0034 x diameter (inches) squared x L (inches) Waste from Commercial Dishwasher ---------CORRECT ANSWER------------ -----Air Gap Laundry Stand Pipe ---------CORRECT ANSWER----------------- 18 - 42" Min 2" Phenuematic Vent size for Sewage Pumps ---------CORRECT ANSWER---- ------------- 1 - 1/4" How many feet does a roof ledge or vertical wall add to roof area --------- CORRECT ANSWER-----------------1/2 of Roof Area How far does sanitary vent have to be from property line ---------CORRECT ANSWER-----------------10 Feet
Vent from window Can be How many feet from window horizontally and vertically ---------CORRECT ANSWER-----------------10' and 2' Testing With Air ---------CORRECT ANSWER-----------------5PSI 15 Mins What kind of backflow on irrigation setup ---------CORRECT ANSWER------- ----------atmospheric type vacuum breaker, a pressure type vacuum breaker or a reduced pressure principle back flow preventor. How many times to inspect back flows ---------CORRECT ANSWER---------- -------Yearly Testing Back flows Should Happen When ---------CORRECT ANSWER------ -----------Install, Repairs, and Annually Drainage Fixture Unit on Lav ---------CORRECT ANSWER----------------- 1 Drainage Fixture Unit on Res. Washer Machine & Bathub --------- CORRECT ANSWER----------------- 2 Drainage Fixture Unit on Res. Toilet ---------CORRECT ANSWER------------- ---- 4
You Vent a sink to prevent what? ---------CORRECT ANSWER----------------- Siphonage You need to pay the prevailing wage on state jobs when you are over what Amount? ---------CORRECT ANSWER-----------------$1, 4" Pipe 150 Feet Long, How many Gallons? ---------CORRECT ANSWER--- --------------230 Gallons A master plumber employs 3 master plumbers, and 6 journeyman. How many apprentices can he have. ---------CORRECT ANSWER----------------- 10 Maximum flow rate at a 60PSI Lavatory ---------CORRECT ANSWER--------- --------2.2GPM how much gallons of water in a cubic foot ---------CORRECT ANSWER------ -----------7. On a commercial Sewage ejector what is required? ---------CORRECT ANSWER-----------------B+C--Ball Valve/Check Valve What is defined as public work in RI? ---------CORRECT ANSWER------------ -----Any Renovation to a public Building.