STANDPIPE SYSTEMS ARE PIPES INSTALLED IN A BUILDING TO TRANSFER WATER TO CONNECTIONS LOCATED INA BUILDING. - Correct Answer HOSE ITS TO INSTALL OR MAINTAIN FIRE PROTECTION SYSTEMS THAT HAVE THE PHYSICAL APPEARANCE OF FIRE EQUIPMENT BUT THAT DON'T PERFORM A FUNCTION. - Correct Answer UNLAWFUL IT IS THE RESPONSIBILITY OF THE TO MAINTAIN THE STANDPIPE SYSTEM. - Correct Answer OWNER IN ABSENCE OF A SPECIFIC DESIGNEE, THE BUILDING OWNER SHALL BE CONSIDERED THE . - Correct Answer IMPAIRMNENT COORDINATOR SYSTEMS FULLY OUT OF SERVICE ARE INDICICATED BY A DISC ON FDNY CONNECTIONS. - Correct Answer WHITE SYSTEMS PARTIALLY OUT OF SERVICE ARE INDICATED BY A DISC ON FDNY CONNECTIONS. - Correct Answer BLUE ONLY FDNY, OWNER, OR MAY PLACE A WHITE OR BLUE DISC ON A SYSTEM - Correct Answer MFSPC, MLP PRIOR TO RETURNING A SYSTEM TO SERVICE, THE SHALL ENSURE THAT THE NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. - Correct Answer IMPAIRMENT COORDINATOR RECORDS SHALL BE AVAILABLE TO ANY REPRESENTATIVE OF THE FIRE DEPARTMENT. - Correct Answer READILY IS A DESIGNED SERIES OF BEAMS USED TO SUPPORT MECHANICAL EQUIPMENT. - Correct Answer DUNNAGE A FIRE DEPT. CONNECTION WAS FORMERLY KNOWN AS A CONNECTION. - Correct Answer SIAMESE THE MEASUREMENT OF SYSTEM PRESSURE UNDER NON-FLOW CONDITIONS IS PRESSURE. - Correct Answer STATIC THE DRY TYPE VALVE IS DESIGNED TO OPEN WHEN THERE IS A OF AIR PRESSURE IN THE STANDPIPE. - Correct Answer DROP THE DRY PIPE VALVE IS USUALLY SET TO TRIP AT PSI ABOVE THE NORMAL TRIP LEVEL. - Correct Answer 15-20 QUICK OPENING DEVICES CONTAIN AN AND AN EXHAUSTER. - Correct Answer ACCELERATOR QUICK OPENING DEVICES ARE AUTOMATICALLY ACTIVATED WHEN A DROP OF PSI IN AIR PRESSURE IS DETECTED. - Correct Answer 2 VALVES ARE USED TO SHUT DOWN PART OF THE SYSTEM WHEN CONDUCTING REPAIRS OR MAINTENANCE. - Correct Answer POST INDICATOR WHEN POST INDICATOR VALVES (PIV) ARE INSTALLED, THE SHOULD BE PAINTED . - Correct Answer RED ROOF MANIFOLD HOSE OUTLETS MUST BE SET BETWEEN INCHES ABOVE THE ROOF LEVEL. - Correct Answer 18-60 A PRESSURE RESTRICTING DEVICE SHALL BE INSTALLED AT HOSE OUTLETS WHERE STATIC PRESS. EXCEEDS PSI. - Correct Answer 80 CHECK VALVES ARE NORMALLY USED IN SYSTEMS USING A GATE VALVE. - Correct Answer SWING IN AN OS&Y VALVE, IF THE STEM IS RAISED ABOVE THE CONTROL WHEEL THE VALVE IS . - Correct Answer OPEN FOR 1938-1968 HOSE OUTLET AND RELEASE RACKS, THE HOSE SHOULD BE KEPT BETWEEN FT AND FT ABOVE THE FLOOR OR LANDING. - Correct Answer 5, 6 TO MAXIMIZE LIFE OF HOSE, IT SHOULD BE KEPT AT TEMPERATURES BETWEEN AND . - Correct Answer 32 DEGREES FAHRENEIT, 100 FAHRENHEIT ACCEPTABLE AIR PRESSURE INSIDE AIR TANKS MAY VARY FROM PSI. - Correct Answer 15-80 INTERIOR SIGNAGE SHALL HAVE A BACKGROUND WITH 1 INCH HIGH LETTERS. - Correct Answer RED, WHITE EXTERIOR SIGNAGE SHALL HAVE A BACKGROUND WITH 1 INCH HIGH LETTERS. - Correct Answer WHITE, RED HOSE MARKES "SUPPLY HOSE" SHALL NOT EXCEED PSI. - Correct Answer 185 PRESSURE REDUCING DEVICES SHALL BE FLOW TESTED WITHA MINIMUM FLOWING DISCHARGE OF GPM - Correct Answer 250