S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS S95 practice test 66 COMPLETE SOLUTIONS
Typology: Exams
1 / 6
This page cannot be seen from the preview
Don't miss anything!
Accessibility - ANSWER-as defined in NPFA admitting close approach:not gaurded by locked doors, elevation, and other effective means Alarm Notification Appliance - ANSWER-A fire alarm system component, such as a bell, horn, speaker, light, text display or vibration device that issues an audible, tactile, and/or visual alert Alarm Signal - ANSWER-A signal indicating an emergency requiring immediate action, such as a signal indicative of fire. Annunciator - ANSWER-A unit containing one or more indicator lamps, alphanumeric displays, or other equivalent means in which each indication provides status information about a circuit, condition or location. Approved Central Station Company - ANSWER-A central station company that has been issued a valid certificate of operation from FDNY. ARCS (Auxiliary Radio Communication System) - ANSWER-In-Building Emergency Radio coomunication system. ARC system is a wireless two-way building communication system for fire department use only central station - ANSWER-A facility that receives alarm signals from a protected premises and retransmits or otherwise reports such alarm signals to the department Defined Fire Alarm System - ANSWER-A fire alarm system or any sub-system thereof that automatically transmits signals to the department or a central station and that is installed in premises which are required to have a fire alarm system. Designated Representative - ANSWER-A person or entity designated by the subscriber who shall be responsible for receiving notifications from the central station company concerning the status of the protective signaling system at the protected premises and who is authorized to take action with respect to such system. Fire alarm control unit or panel(FACP,FCS) - ANSWER-System component that receives input from automatic and manual fire alarm devices and may provide power to detection devices or communication devices.
Fire Alarm Signal - ANSWER-A signal initiated by a fire alarm-initiating device such as a manual fire alarm box (pull station), automatic fire detector, water-flow switch, or other device whose activation is indicative of the presence of a fire or fire signature. Elevator lobby smoke Detector - ANSWER-Are smoke detectors thtat when activated will recall elevators automatically into the designated landing Duct smoke detectors - ANSWER-Smoke detectors that sample the air moving through the air distribution system ductwork or plenum; upon detecting smoke, the detector sends a signal to shut down the air distribution unit, close any associated smoke dampers, or initiate smoke control system operations. Nuisance Alarm - ANSWER-A fire alarm signal caused by malfunction or improper operation of a fire alarm system or component. Initiating device - ANSWER-A system component that originates transmission of a change-of-state condition, such as in a smoke detector, manual fire alarm box, or supervisory switch. shall - ANSWER-indicates a mandatory requirements Impairment Coordinator - ANSWER-Person responsible for ensuring the proper safety precautions are taken when the protection system is placed out of service (designated by the owner). smoke detector maintenance - ANSWER-Work, including but not limited to, repair, replacement, and service, performed to ensure that equipment operates properly. Fire Protection System - ANSWER-Any fire alarm or fire-extinguishing device or system that is designed and installed to detect, control or extinguish a fire, or to alert the occupants or the fire department that a fire has occurred or any combination of these smoke detector maintenance company certificate - ANSWER-A certificate issued by the commissioner to a person engaged in the business of performing smoke detector cleaning and testing, which authorizes such person to engage in such business and supervise the performance of such cleaning and testing by certificate of fitness holders. FLSD - ANSWER-FIRE LIFE SAFETY DIRECTOR Fire Alarm Control Panel (FACP) - ANSWER-contains electronics that control and monitor the fire alarm system. Lamp Test - ANSWER-This function is used on some FACP's to check the condition of the light emitting diodes (LEDs) on the FACP.
smoke detector maintenance company certificate - ANSWER-A certificate issued by the commissioner to a person engaged in the business of performing smoke detector cleaning and testing, which authorizes such person to engage in such business and supervise the performance of such cleaning and testing by certificate of fitness holders. smoke detector maintenance company certificate - ANSWER-A certificate issued by the commissioner to a person engaged in the business of performing smoke detector cleaning and testing, which authorizes such person to engage in such business and supervise the performance of such cleaning and testing by certificate of fitness holders. Initiating device - ANSWER-A system component that originates transmission of a change-of-state condition, such as in a smoke detector, manual fire alarm box, or supervisory switch. Initiating device - ANSWER-A system component that originates transmission of a change-of-state condition, such as in a smoke detector, manual fire alarm box, or supervisory switch. smoke damper (definition) - ANSWER-smoke dampers open and close when required to provide fresh air or to stop smoke passage Fire Dampers - ANSWER-Fire dampers close when a rise in temperture occurs and stay shut to stop fire from passing through a barrier Elevator Recall - ANSWER-The fire Alarm system integrates with elevator controls to recall elevator cars to a designated landing floor in the event of an alarm Addressable System Smoke Detectors - ANSWER-Provide an alarm indication to a control unit. In addition,they also signal the location of the alarm Building fire protection features- activated by the Fire Alarm System - ANSWER-smoke dampers, fire dampers,elevator recall, door release (where connected to FACP) Smoke Detectors features that increase their ability to provide fire protection - ANSWER-Addressable System smoke detector, Intelligent system smoke detectors, smoke detector with control output functions Heat detectors are available in two general types - ANSWER-Rate or rise and Fixed Temperature Fixed heat temperature detector - ANSWER-when activated have to be replaced
Rate-of-Rise Heat Detector - ANSWER-when activated does not need to be placed Intelligent heat detector - ANSWER-when activated usally reset themselves alarms and detectors - ANSWER-should not be painted Alarm Log book - ANSWER-an alarm logbook shall be maintained on the premises, at the buildings main Fre Alarm Control Panel FSP(Fire Safety and Evacuation plan)Log BOOK - ANSWER-Log book is different from the alarm log book,it could be bounded with the fire alarm log book but must be properly labeled and divided Audio and Visual Notification Devices - ANSWER-Speaker, speaker strobe,horn strobe, strobe,Gong bells Alarm log book - ANSWER-each section shall have a sufficent number of pages to allow for entries for at least one year Out of service situations and impairment Coordinator - ANSWER-An out of service system is a fire protection system that is not fully functional; or whose operation is impaired or not in good working order Fire Alarm system off-line - ANSWER-Anytime a fire alarm system is to be activated during a test ,inspection, or fire drill, it is mandatory to take the system "offline" by notifying the FDNY approved central station company monitoring the fire alarm before hand to prevent the unnecessary dispatching of the fire department. It is not necessary to take the system offline when the speaker audibility test are being conducted out of service signage - ANSWER-A certificate of fitness holder must notify his/her supervisor and a put placard over the defective box indicating that the device is out of service Requirements for out of service - ANSWER-Where a required fire protection system is out of servive , the fire department shall be notified immediately and unless otherwise directed by the fire commissioner, either the building shall be evacuated or a fire watch shall be maintained by one or more persons holding a certificate of fitness for fire gaurd.Any other actions as the fire commissioner may direct, in additon to or in lieu of such measures, shall also be undertaken, until the protection system has been returned to service. Where utilized, fire gaurds shall br provided with at lead one approved means for notification to the fire depatment and their only duty shall be to perform constant patrols of the protected premises and keep watch for fires.