TCFP FIRE INSPECTOR I EXAM QUESTIONS AND CORRECT DETAILED ANSWERS 2025 (VERIFIED ANSWERS) WITH RATIONALES
Typology: Exams
1 / 28
This page cannot be seen from the preview
Don't miss anything!
D. Owner's manual Local or state fire codes specify the roles and authority of fire inspectors.
D. Metals Class A fires involve materials like wood, paper, and cloth. 11.An egress system includes all of the following EXCEPT: A. Exit access B. Exit C. Interior decoration D. Exit discharge Interior decoration is not part of the means of egress. 12.During a fire inspection, a blocked exit door is considered: A. An immediate life safety hazard B. A minor infraction C. A non-compliance issue D. A maintenance concern Blocked exits pose a serious threat to occupants during emergencies. 13.When are fire doors required to be self-closing? A. In all classrooms B. In garages C. In rated fire barrier walls D. At exterior exits Fire doors in rated assemblies must close automatically to prevent fire spread. 14.Fire lane obstructions are most commonly enforced by: A. Utility departments
B. Fire inspectors C. Police officers D. Architects Fire inspectors are responsible for identifying and addressing fire lane issues. 15.A fire extinguisher with a rating of 2A10BC is effective on how many types of fires? A. 1 B. 2 C. 3 D. 4 2A10BC is rated for Class A, B, and C fires. 16.What is the minimum clearance required around a fire hydrant? A. 3 feet B. 18 inches C. 5 feet D. 10 feet Three feet is the standard clearance to allow firefighter access. 17.Who has the final authority on code interpretation during an inspection? A. Building owner B. Local government C. Authority Having Jurisdiction (AHJ)
21.Portable fire extinguishers should be visually inspected: A. Every 5 years B. Only after use C. Monthly D. Semi-annually NFPA 10 requires monthly visual checks for accessibility and condition. 22.A common violation found in commercial kitchens is: A. Lack of smoke detectors B. Grease buildup in hoods and ducts C. Use of plastic cookware D. Storage of frozen goods Grease buildup is a major fire hazard in cooking environments. 23.What does a red tag on a fire suppression system indicate? A. Ready for use B. Under maintenance C. Impaired or out of service D. Inspected and passed A red tag signals that the system is not operational. 24.Combustible storage in electrical rooms is: A. Permitted with safeguards B. Allowed for 30 minutes C. Prohibited D. Acceptable with a permit Combustibles in electrical rooms increase fire risk and are prohibited.
25.During an inspection, which document should be verified for fire alarm systems? A. Inspection and testing report B. Business license C. Evacuation plan D. Insurance binder Inspectors should ensure alarm systems are maintained and tested per code. 26.What agency accredits fire service certification programs in Texas? A. FEMA B. ISO C. TCFP D. NFPA The Texas Commission on Fire Protection (TCFP) oversees fire certifications. 27.Which system uses a fusible link to operate during high heat? A. Fire alarm B. Smoke detector C. Fire suppression hood system D. Emergency lighting Fusible links trigger suppression systems in commercial kitchens. 28.What is the maximum height for fire extinguisher mounting if it weighs more than 40 lbs? A. 36 inches
32.Where should exit signs be located? A. At all exit doors and along exit paths B. Only at final exits C. Next to windows D. In the fire control room Exit signs must clearly mark all exits and paths leading to them. 33.A Knox Box is used to: A. Provide emergency key access to fire responders B. Store inspection records C. Mount extinguishers D. Lock hazardous chemicals Knox Boxes contain keys for rapid access during emergencies. 34.Sprinkler heads should be spaced to allow for: A. Accessibility B. Complete water coverage C. Aesthetic appeal D. Energy savings Proper spacing ensures sprinkler effectiveness in covering the fire area. 35.Smoke detectors must be located: A. In each sleeping area and hallway B. Only in kitchens C. At building entrances D. On exterior walls Residential codes require detectors in and near sleeping areas.
36.Combustible materials must be stored at least how far from the ceiling in a non-sprinklered building? A. 12 inches B. 24 inches C. 36 inches D. 6 inches In non-sprinklered buildings, at least 24 inches of clearance is required. 37.A fire wall is designed to: A. Reflect heat B. Cool hot gases C. Prevent fire spread between areas D. Vent smoke Fire walls compartmentalize structures to slow or stop fire spread. 38.Tampering with fire protection equipment is: A. Sometimes allowed B. A code violation C. Acceptable in drills D. Done by inspectors only Tampering is prohibited and may result in citations or legal consequences. 39.How often should fire alarm systems be tested by a qualified technician? A. Every 6 months B. Every 2 years C. Annually
C. Unsecured exits D. Dust accumulation Stacking combustibles too high impedes sprinkler performance. 44.Combustible materials stored near electrical panels must maintain what clearance? A. 12 inches B. 18 inches C. 24 inches D. 36 inches Clearances around electrical panels prevent fire hazards and allow access. 45.To ensure effectiveness, a fire watch must: A. Include police officers B. Last at least 2 hours C. Monitor for fire and report immediately D. Be off-site A fire watch involves on-site monitoring for fire risks. 46.When conducting inspections, fire inspectors must always: A. Wear turnout gear B. Carry identification C. Have a building key D. Be accompanied by police Identification verifies the inspector’s authority to conduct inspections.
47.The flame spread rating of interior finishes is determined by: A. ASTM E84 test B. Fire drills C. Occupant load D. Visual assessment The ASTM E84 test measures flame spread and smoke development. 48.An acceptable fire extinguisher must be: A. Tagged, charged, and accessible B. Yellow C. More than 10 years old D. Wall-mounted above 6 feet Extinguishers must be maintained and easily reachable. 49.What triggers a wet-pipe sprinkler system? A. Smoke B. Heat detectors C. Heat that causes the sprinkler bulb to burst D. Alarm pull station Wet-pipe sprinklers discharge water when the heat-sensitive element activates. 50.Which code outlines minimum fire prevention standards in Texas? A. NFPA 72 B. Life Safety Code C. International Fire Code (IFC)
This ensures accessibility to all building occupants, including those with disabilities. 54.Which is a typical requirement for exit stairways? A. Carpeted flooring B. Enclosure with rated fire-resistive construction C. Locking devices on exit doors D. Use as storage areas Stairways must be enclosed to prevent fire and smoke migration. 55.What is required on the exterior of buildings with fire department connections (FDCs)? A. Lockboxes B. Emergency lights C. Signage indicating FDC location D. Pull stations Signage helps responders locate the FDC quickly in emergencies. 56.Which standard applies to the installation of sprinkler systems? A. NFPA 25 B. NFPA 13 C. NFPA 70 D. NFPA 10 NFPA 13 governs the design and installation of automatic sprinkler systems. 57.A violation that poses immediate danger to life is classified as: A. Moderate
B. Imminent hazard C. Deferred hazard D. Administrative concern Such hazards require urgent corrective action. 58.What does a blue placard in the NFPA 704 system represent? A. Health hazard B. Flammability hazard C. Reactivity D. Special hazard The blue section rates the material’s health risk. 59.In a hazardous materials occupancy, what code regulates the maximum quantity allowed? A. Building Code B. NFPA 1 C. International Fire Code (IFC) D. Local zoning ordinance The IFC defines Maximum Allowable Quantities (MAQs) for hazardous materials. 60.Combustible liquids have a flash point: A. Below 100°F B. At or above 100°F C. Over 500°F D. No flash point
B. Covered with tile C. Fire-resistance rated D. Kept under 10 feet in length Rated corridors prevent the spread of fire and smoke during evacuation. 65.What must be done before reoccupying a building after a fire? A. Fire watch established B. Approval from the AHJ C. Written report by fire investigator D. Insurance inspection completed The AHJ ensures the building is safe for reentry. 66.What is the maximum travel distance to a fire extinguisher for Class B hazards? A. 25 feet B. 35 feet C. 50 feet D. 100 feet Per NFPA 10, the limit for Class B hazards is 50 feet. 67.To determine occupancy classification, the inspector must review: A. Fire loss history B. Intended use of the space C. Weather conditions D. Owner preference Occupancy classification is based on how the space is used.
68.Flammable materials stored in cabinets must be limited to: A. 30 gallons of any liquid B. Unlimited with ventilation C. Specific gallon limits based on class D. Daily use amounts only Codes define specific limits for Classes IA, IB, and IC liquids. 69.What type of suppression system uses dry chemicals? A. Sprinkler B. Dry chemical system C. Halon system D. CO2 system Dry chemical systems are common in kitchens and paint booths. 70.During a fire inspection, what should be noted about fire doors? A. Age of hardware B. Operational condition and clearances C. Type of paint D. Door knob design Fire doors must operate properly and meet clearance requirements. 71.What is the minimum separation required between above-ground propane tanks and buildings (in most codes)? A. 1 foot B. 10 feet C. 25 feet