Download Wiring Diagram and Key Details for Various Temperature Sensors and more Lecture notes Chemistry in PDF only on Docsity!
Applicable Sensors
Wiring Diagram
Temperature Sensors (Celsius)
Key Details
Tolerance = +4/-2 °C (-40-125 °C)
Tolerance = ±2 °C (0-70 °C)
Tolerance = ±1 °C at 25 °C
Measurement Range = -40 °C to 121 °C
VCC = 3-30 Vdc
*Temp out is a voltage output referenced to COM (-)
Com (-)
Com (-)
Temp Out
VCC (+)
TC120, TC
Power
Common
Temperature Output
Pin A
Pin B
Pin C
Room Temperature (25°C) = 750mV
0
200
400
600
800
1000
1200
1400
1600
1800
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
VOUT
(mV)
Temperature (°C)
Celsius Sensors Output
Temperature Output
Temperature Sensors (Celsius)
TC120, TC
Temperature Sensors (Celsius)
Temperature Output
Key Details
Tolerance = ±3 °C
Tolerance = ±2 °C at 25 °C
Measurement Range = 2.5 °C to 100 °C
*IEPE Open Circuit Voltage = 18-30 Vdc
*IEPE Constant Current = 2-10 mA
* Temp out is a voltage output referenced to COM (-)
TA102, TA104, TA117, TA118, TA131, TA133, TA134, TA135, TA
Room Temperature (25°C) = 250mV 0
200
400
600
800
1000
1200
2.5 7.5 12.5 17.5 22.5 27.5 32.5 37.5 42.5 47.5 52.5 57.5 62.5 67.5 72.5 77.5 82.5 87.5 92.5 97.
Vout (mV)
Temperature (°C)
Celsius Sensors Output
Applicable Sensors
Wiring Diagram
M12 Temperature Sensors (Celsius)
Key Details
Tolerance = ±3 °C
Tolerance = ±2 °C at 25 °C
Measurement Range = 2.5 °C to 100 °C
*IEPE Open Circuit Voltage = 18-30 Vdc
*IEPE Constant Current = 2-10 mA
*Temp out is a voltage output referenced to COM (-)
Com (-)
Com (-)
Temp Out
2-10 mA
IEPE Constant
Current Supply
TA102, TA104, TA
Power
Common
Temperature Output
Pin 1
Pin 2
Pin 4
Vibration^ Signal^ +
Current Return
Com (-)
NC
Applicable Sensors
Wiring Diagram
M12 Temperature Sensors (Celsius)
Key Details
Tolerance = +4/-2 °C (-40-125 °C)
Tolerance = ± 2 °C (0-70 °C)
Tolerance = ±1 °C at 25 °C
Measurement Range = -40 °C to 121 °C
VCC = 3-5 Vdc
*Temp out is a voltage output referenced to COM (-)
Com (-)
Com (-)
Com (-)
Temp Out^ Vibration Signal
VCC (+)
TA312, TA
Power
Common
Signal Output
Temperature Output
Pin 1
Pin 2
Pin 3
Pin 4
M12 Temperature Sensors (Celsius)
Temperature Output
Room Temperature (25°C) = 750mV
0
200
400
600
800
1000
1200
1400
1600
1800
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
VOUT
(mV)
Temperature (°C)
Celsius Sensors Output
TA312, TA
Temperature Sensors (Kelvin)
Room Temperature (25°C) = 2981.5mV
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
VOUT
(mV)
Temperature (°C)
Kelvin Temperature Sensor Output (Celsius)
Room Temperature (298.15K) = 2981.5mV
VOUT
(mV)
Temperature (K)
Kelvin Temperature Sensor Output (Kelvin)
Temperature Output
TK120, TK
Applicable Sensors
Wiring Diagram
Temperature Sensors (Kelvin)
Key Details
Tolerance = ±4 °C (typical); ± 9 MAX
Tolerance = ±2 °C at 25 °C (typical); ±6 MAX
Measurement Range = -40 °C to 100 °C (233.15 K to 373.15 K)
IEPE supply can be used for the temperature circuit, however it cannot exceed 5mA.
Note: Kelvin sensors are sensitive to self heating, so the lowest possible supply current should be used
*IEPE Open Circuit Voltage = 18-30 Vdc
*IEPE Constant Current = 2-10 mA
*Temp out is a voltage output referenced to COM (-)
TA172, TA174, TA
Com (-)
Com (-)
Temp Out
2-10 mA
IEPE Constant
Current Supply
Power
Common
Temperature Output
Pin A
Pin B
Pin C
Vibration^ Signal^ +
Current Return
Com (-)
.4-5 mA
Constant Current
Supply
Applicable Sensors
Wiring Diagram
M12 Temperature Sensors (Kelvin)
Key Details
Tolerance = ±4 °C (typical); ±9 MAX
Tolerance = ±2 °C @ 25 °C (typical); ±6 MAX
Measurement Range = -40 °C to 100 °C (233.15 K to 373.15 K)
IEPE supply can be used for the temperature circuit, however it cannot exceed 5mA.
Note: Kelvin sensors are sensitive to self heating, so the lowest possible supply
current should be used
*IEPE Constant Current = 2-10 mA
*IEPE Open Circuit Voltage = 18-30 Vdc
*Temp out is a voltage output referenced to COM (-)
TA172, TA174, TA
Com (-)
Com (-)
Temp Out
2-10 mA
IEPE Constant
Current Supply
Power
Common
Temperature Output
Pin 1
Pin 2
Pin 3
Vibration^ Signal^ +
Current Return
Com (-)
.4-5 mA
Constant Current
Supply
NC
TA172, TA174, TA
M12 Temperature Sensors (Kelvin)
Room Temperature (25°C) = 2981.5mV
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
VOUT
(mV)
Temperature (°C)
Kelvin Temperature Sensor Output (Celsius)
Room Temperature (298.15K) = 2981.5mV
VOUT
(mV)
Temperature (K)
Kelvin Temperature Sensor Output (Kelvin)
Temperature Output
TR102, TR104, TR133, TR
R0 (0°C) = 100Ω
Room Temperature (25°C) = 109.73Ω
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
Resistance (
Temperature (°C)
RTD Output
Temperature Output
Applicable Sensors
RTD Sensors
Key Details
R0 = R at 0°C = 100 Ω
R0 tolerance = ± .2 Ω
Temp Tolerance = ± .5 °C
(or .8% of temp, whichever is greater)
*IEPE Open Circuit Voltage = 18-30 Vdc
*IEPE Constant Current = 2-10 mA
Key Details
Applicable Sensors
Wiring Diagram
Loop Power Temperature Sensors
Tolerance = +4/-2 °C (-40-125 °C)
Tolerance = ±2 °C (0-70 °C)
Tolerance = ±1 °C at 25 °C
Measurement Range = -40 °C to 85 °C
VCC = 15-30 Vdc
*Temp out is a voltage output referenced to COM (-)
Com (-)
Com (-)
Temp Out
4-20 mA Signal
VCC (+)
LP232, LP234, LP332, LP
Power
Common
Temperature Output
Pin A
Pin B
Pin C