TEXAS FIRE EXTINGUISHER LATEST EXAM QUESTIONS WITH CORRECT AND VERIFIED ANSWERS.pdf, Exams of Medicine

TEXAS FIRE EXTINGUISHER LATEST EXAM QUESTIONS WITH CORRECT AND VERIFIED ANSWERS.pdf

Typology: Exams

2024/2025

Available from 07/02/2025

samuel-tutor
samuel-tutor 🇺🇸

59 documents

1 / 12

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
TEXAS FIRE EXTINGUISHER LATEST EXAM
QUESTIONS WITH CORRECT AND VERIFIED
ANSWERS, 100% GUARANTEE PASS
QUESTION: service and servicing - ANSWER-mean servicing a portable fire extinguisher or a
fixed fire extinguisher system by charging, filling, maintaining, recharging, refilling, repairing,
or testing.
QUESTION: unless the firm holds a registration certificate issued by the department,a firm may
not engage in the business of - ANSWER-installing or servicing portable fire extinguishers or
planning,certifying,installing or servicing fixed fire extinguisher systems. selling is allowed
QUESTION: hydrostatic testing of fire extinguishers that is not performed under he
specifications of the united states department of transportation - ANSWER-must be performed in
the manner recommended by the national fire protection association
QUESTION: the department may not issue a registration certificate under this chapter -
ANSWER-unless the applicant files with the department of evidence of a general liability
insurance policy
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download TEXAS FIRE EXTINGUISHER LATEST EXAM QUESTIONS WITH CORRECT AND VERIFIED ANSWERS.pdf and more Exams Medicine in PDF only on Docsity!

TEXAS FIRE EXTINGUISHER LATEST EXAM

QUESTIONS WITH CORRECT AND VERIFIED

ANSWERS, 100% GUARANTEE PASS

QUESTION: service and servicing - ANSWER-mean servicing a portable fire extinguisher or a fixed fire extinguisher system by charging, filling, maintaining, recharging, refilling, repairing, or testing.

QUESTION: unless the firm holds a registration certificate issued by the department,a firm may not engage in the business of - ANSWER-installing or servicing portable fire extinguishers or planning,certifying,installing or servicing fixed fire extinguisher systems. selling is allowed

QUESTION: hydrostatic testing of fire extinguishers that is not performed under he specifications of the united states department of transportation - ANSWER-must be performed in the manner recommended by the national fire protection association

QUESTION: the department may not issue a registration certificate under this chapter - ANSWER-unless the applicant files with the department of evidence of a general liability insurance policy

QUESTION: 100,000 - ANSWER-combined single limits for bodily injury and property damage for each occurrence

QUESTION: 300,000 - ANSWER-aggregate for all occurrences for each policy

QUESTION: Fixed fire extinguisher system - ANSWER-an assembly of piping,conduits or containers that convey liquid ,powder or gases

QUESTION: Portable fire extinguishers - ANSWER-any device that contains liquid,powder,or gases for suppressing or exstinguish fires

QUESTION: portable fire extinguisher inspection - ANSWER-means a monthly inspection to ensure that a portable fire extinguisher is in the designated location,has not been subject to tampering,does not have physical damage.

QUESTION: an individual other than an apprentice must hold a license issued by the department before - ANSWER-installing or servicing portable fire extinguishers,servicing,certifying preengineered fixed fire extinguisher systems,planning,supervising,certifying installation fixed fire systems

QUESTION: 30 days - ANSWER-the amount of time the fire marshal has to send the results of the examination

QUESTION: 14 days - ANSWER-the amount of time the fire marshal has to send the results of the examination if its conducted by a testing service

QUESTION: 90 days - ANSWER-the amount of time the fire marshal has to send the test results if delayed

QUESTION: an individual may not install or service portable fire extinguishers or fixed fire extinguisher systems as an apprentice unless the individual - ANSWER-holds an apprentice permit issued by the department

QUESTION: an apprentice may perform a service only - ANSWER-under the direct supervision of an individual who holds a license and works for the same firm as the apprentice

QUESTION: notice of license expiration - ANSWER-30 days

QUESTION: a firm or individual whos registration certificate or license has been expired for more than 90 days but less than 2 years may - ANSWER-renew the certificate or license by paying the department all unpaid renewal fees an a fee that is equal to the initial fee for the certificate or license.

QUESTION: a firm or individual whos license or certificate has been expired for two years - ANSWER-may not renew the certificate or license and must obtain a new registration certificate or license

QUESTION: a prohibited practice - ANSWER-the selling,installing,service or recharge a carbon tetrachloride fire extinguisher

QUESTION: the lease,sell,service or install of a portable fire extinguisher,fixed fire extinguisher system or extinguisher equipment is prohibited unless - ANSWER-it carries an approval label or listing label issued by a testing laboratory approved by the department

QUESTION: an offence under section 6001 - ANSWER-is a class b misdemeanor

QUESTION: DOT nonspecification - ANSWER-all fire extinguisher cylinders manufactured and tested but not stamped with a specification number.

QUESTION: if changing ownership you must alert state fire marshal in - ANSWER-14 days

QUESTION: if changing corporate officers you must alert state fire marshal in - ANSWER- days

QUESTION: type pl license - ANSWER-for planning,supervising,certifying,installing or servicing of all fixed systems other than pre-engineered systems. a system planning licensee may also perform supervise or certify the installation or servicing of all pre-engineered fixed systems and portable fire extnguishers.

QUESTION: type a license - ANSWER-for certifying or servicing the installation of all fixed fire extinguisher systems, other than pre-engineered systems; or for installing, certifying, or servicing all pre-engineered fixed fire extinguisher systems, and certifying and servicing of portable extinguishers.

QUESTION: type b license - ANSWER-for servicing, certifying, and low pressure hydrostatic testing of portables

QUESTION: type k license - ANSWER-for installing, certifying, or servicing pre-engineered fixed fire extinguisher systems for the protection of cooking areas and certifying and servicing portable extinguishers.

QUESTION: Revised license - ANSWER-The change of a licensee's registered firm or mailing address requires a revised license.

Within 14 days after the change requiring the revision, the license holder or registered firm must submit written notification of the necessary change accompanied by the required fee.

QUESTION: a registered firm must notify the state fire marshal within how many days after termination of employment of a license - ANSWER-14 days

QUESTION: pocket permit - ANSWER-a permit holder must carry a pocket permit or identification while engaging in the business

QUESTION: revised permits - ANSWER-the change of a permittee's employer, home address or mailing address requires a revised permit within 14 days

texas as a professional engineer or a copy of the national institute for certification in engineering technologies

QUESTION: type a license test will include questions on the following - ANSWER-this subchapter and insurance code chapter 6001 installing and servicing of portables,fixed systems, installing and servicing pre engineered fixed fire extinguisher systems for the protection of cooking areas

QUESTION: no test is required for a licensee whose license is renewed within - ANSWER- years of expiration

QUESTION: a service tag certifying the work the licensee performed must be - ANSWER- securely attached to the portable extinguisher on completion of the work

QUESTION: the back of the service tag must be plainly marked with the words - ANSWER-no listing mark

QUESTION: on completion of the installation of a pre-engineered fixed fire extinguisher systems a licensee authorized to certify pre engineered fixed fire extinguishing systems must

place - ANSWER-an installation label on the system to certify that the system was installed in compliance with the manufacturers installation manuals and specifcations

QUESTION: the licensee whose signature appears on the installation label must - ANSWER-be present for the final test of the system prior to certification

QUESTION: on completion of the installation of a fixed fire extinguisher system other than a pre-engineered system - ANSWER-a type a or type pl licensee must place an installation label on the system to certify that the system was installed

QUESTION: the fixed temperture sensing elements of the fusible metal alloy type, replaced while servicing a kitchen hood fire extinguisher system - ANSWER-must bear the manufacturers date stamp, which must be within one year of the date of the replacement,the year of manufacture, temperature, and quantity

QUESTION: after any service, the licensee must - ANSWER-complete a service tag in detail,indicating all work that is done, and then attach the tag to the portable or fixed system

QUESTION: a stamped signature is - ANSWER-prohibited