VIVINT CEU Certification Actual Exam: Questions and Answers, Exams of Workplace Safety

A comprehensive set of questions and answers for the vivint ceu certification exam. It covers various topics related to security systems, fire safety, access control, and customer service. Valuable for individuals preparing for the vivint ceu certification exam, offering insights into the key concepts and practical applications.

Typology: Exams

2024/2025

Available from 03/08/2025

Tutornurse
Tutornurse 🇺🇸

3.5

(2)

3.3K documents

1 / 30

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
VIVINT CEU CERTIFICATION ACTUAL EXAM
WITH CORRECT ACTUAL QUESTIONS AND
CORRECTLY WELL DEFINED ANSWERS LATEST
2025 ALREADY GRADED A+
The minimum headroom of working spaces about service equipment, switch
boards,
panel boards, or motor control centers should be ___. - ANSWERS-6.5 ft.
Round access openings in a manhole shall not be less than ___ mm in diameter.
- ANSWERS-650 mm
Manhole covers should be over ___ or otherwise designed to require the use of
tools to
open. - ANSWERS-100 lbs.
In all cases, the work space should permit at least a ___ degree opening of
equipment
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e

Partial preview of the text

Download VIVINT CEU Certification Actual Exam: Questions and Answers and more Exams Workplace Safety in PDF only on Docsity!

VIVINT CEU CERTIFICATION ACTUAL EXAM

WITH CORRECT ACTUAL QUESTIONS AND

CORRECTLY WELL DEFINED ANSWERS LATEST

2025 ALREADY GRADED A+

The minimum headroom of working spaces about service equipment, switchboards, panel boards, or motor control centers should be ___. - ANSWERS-6.5 ft. Round access openings in a manhole shall not be less than ___ mm in diameter.- ANSWERS-650 mm

Manhole covers should be over ___ or otherwise designed to require the use oftools to open. - ANSWERS-100 lbs. In all cases, the work space should permit at least a ___ degree opening ofequipment

doors or hinged panels. - ANSWERS-90 degrees What is the main purpose of a security system? - ANSWERS-Keep threats fromreaching their targets

Who is not a "stakeholder" in a security system project? - ANSWERS-The PoliceDepartment

One security design principle is called: "defense in depth." Which one of thefollowing is not part of the "4 D's?" - ANSWERS-Detain Hiding a spare key to your house outside is: - ANSWERS-Not recommended A successful service technician: - ANSWERS-Always tests the system beforeleaving the job

State licensing for alarm companies has proven to be a part: - ANSWERS-Theaccountability needed to reduce false alarms

The false alarm reduction method known as Enhanced Call Verification: -ANSWERS-Requires 2 different phone numbers from the call list to be called before dispatching the police

What is the primary concern of a code or standard? - ANSWERS-Life safety A basic system consists of what components? - ANSWERS-All the above Which imaging devices the most commonly used with analog video systems? -ANSWERS-CCD sensors

Which size imaging device is the most commonly used with analog videosystems? - ANSWERS-1/3"

What type of signal does a CCTV camera generate? - ANSWERS-Base band According to the FBI Uniform Crime Report, a burglary occurs every: - ANSWERS-14.4 Seconds

Most residential burglaries occur... - ANSWERS-In broad daylight The common goal of the Electronic Security and Life Safety industry is to: -ANSWERS-Improve the safety, peace of mind, and quality of life of the customer

CSAA is the acronym for: - ANSWERS-Central Station Alarm Association An alarm company yard sign is: - ANSWERS-A good burglar deterrent

What is the proper type of coax to use and video system? - ANSWERS-CopperBraid

T/F? You can install a CS-Lens on a CS-Mount camera with a 5mm spacer ring. -ANSWERS-False

Which spot filter is considered better? - ANSWERS-F The use of UTP "unshielded twisted-pair" uses category 1 or better cable totransmit video instead of using coax. - ANSWERS-False

Which of the following might be used with an outdoor housing? - ANSWERS-Allthe above

A PTZ can be controlled by the following means with the correct hardware inplace. - ANSWERS-All the above

What is the most common type of the following customer service scenarios? -ANSWERS-In-person

Which of the following is not considered a barrier of customer service? -ANSWERS-Internal issues

T/F? Protons have a positive charge. - ANSWERS-True Insulators restrict the movement of electrons. - ANSWERS-True Resistors restrict the flow of electrical current - ANSWERS-True Using Ohm's Law, what is the voltage if we have 2 Amps and 6 Ohms ofresistance? - ANSWERS-

Using Ohm's Law, what is the resistance in a circuit if there are 24 Volts and 6Amps? - ANSWERS-

Using Watt's Law, what are the Amps required if there are 120 Volts and a 60Watt bulb? - ANSWERS-

Determine Volt-amps if we know the voltage is 24 Volts and 3 Amps -ANSWERS-

If the number of turns are greater on the primary side of the transformer vs thesecondary side, it is considered a step down transformer. - ANSWERS-True

If you connect two 12 volt batteries in parallel you will get 24 VDC output -ANSWERS-False

A normally open circuit is in a conductive state before any state change. -ANSWERS-False

When reading mA or Amps on your meter, the probes go in series with the itemyou are checking. - ANSWERS-True

An Unsupervised detection circuit: - ANSWERS-Cannot detect beyond ashortened circuit

VOIP is an acronym for: - ANSWERS-Voice over internet protocol A dry contact is a description of a: - ANSWERS-Relay output When is a combination alarm system used for burglary and fire? - ANSWERS-When it is regarded as a fire alarm

The bridge rectifier/ filter Circuit in an alarm panel provides: - ANSWERS-D.C.voltage

Low-power wireless detection devices report to the: - ANSWERS-Control Panel A siren could be directly connected to a(n): - ANSWERS-Wet output

Here is the sequence of operation for ACS controlled door. Select the answerthat doesn't belong. - ANSWERS-Wait until guard provides input

ACS are capable of integrating with which of the following systems? Pleaseselect all that apply. - ANSWERS-Fire/life safety Video surveillance systems Human resources Here is a list of common ACS software features. Select the answer that doesn'tbelong. - ANSWERS-Replace existing fire alarm system

Which of the following is true for magnetic card? - ANSWERS-Oldest cardtechnology

A residential sale is generally made in: - ANSWERS-One visit Typically the buyout on an early termination of the contract by the customer is:- ANSWERS-75% to 80%

An alarm system provides: - ANSWERS-Detection and reporting No building or structure shall be occupied without a: - ANSWERS-Certificate ofoccupancy

Drawings should have symbols that are: - ANSWERS-Universal A document indicating what the customer received is a: - ANSWERS-Sign-offsheet

Federal law has a right to resend rule that gives the customer a _______"cooling off" period once the contract is signed. - ANSWERS-3 day

If a drawing indicates coverage of a detection device, it is important not to: -ANSWERS-Exaggerate

Software for an alarm system should be stored: - ANSWERS-On-site Writing on the alarm wiring with a permanent marker for identification in thealarm panel is: - ANSWERS-Not recommended

Which class of fire extinguishers would be used for fire created by grease orother fatty substances? - ANSWERS-Class K

Which of these elements is not a part of the fire triangle? - ANSWERS-Argon Manual fire alarm boxes shall be located within _______of each exit doorwayon each floor - ANSWERS-5 feet

Which of the following is not required in OPR design? - ANSWERS-Location awayfrom city limits

Which one of the following is not a kind of OPR? - ANSWERS-Fast food hold upalarm

Which stakeholders determine the appropriate OPR? Check all that apply: -ANSWERS-Insurance companies The customer AHJ

Which one of the following lead to the development of the first OPR? -ANSWERS-Invention of the telephone and telegraph

Which three are common Fire OPR? - ANSWERS-UL Listed Fire Alarm CentralStation Police and fire stations Proprietary supervising station

What three factors may determine that a UL Central station is required? Selectall that apply - ANSWERS-Insurance company demands AHJ directives High value merchandise Check the two answers the describe OPR advantages. - ANSWERS-Preventscompromise my emergency on premise event The Economy of scale/ shared resources In the case of fire alarm systems what is the first requirement - ANSWERS-Meetall applicable codes standards and regulations

What does OSHA stand for? - ANSWERS-Occupational Safety and HealthAdministration

Since OSHA was founded, Workplace deaths dropped from an average of 38 to__ a day - ANSWERS-

Which of the following is not a common hazard in fall related injuries? -ANSWERS-Unsecured doors and windows

Which of the following aspects of OSHA enforcement overseas private sectoremployees - ANSWERS-Jurisdiction

T/F? The recommended technique for carrying any Power Tool is by the cord. -ANSWERS-False

Electric switches have a lot in common with: - ANSWERS-Water faucets Which of the following is a secondary factor in determining the severity of anelectrical shock? - ANSWERS-The general health of the body When modifying a electrical equipment you must stay in compliance with OSHAcodes. - ANSWERS-True

According to the NFPA 72, the loudest an audible fire alarm notificationappliance can be is ___ decibels. - ANSWERS- Temporal 3 audible: - ANSWERS-Will trigger a bed shaker Audible requirements in sleeping rooms call for a minimum of ___ decibels atpillow level. - ANSWERS- A closed door between the sounder and mattress can cause a loss of ___decibels. - ANSWERS-10 to 24

Holmes moved his alarm business from Boston to New York City because -ANSWERS-The people of Boston were skeptical about having anything electrical in their homes George Milliken's patent improved the burglar alarm by - ANSWERS-Having thefirst zoned alarm system

Three functions of an alarm system are ______, notification, and control. -ANSWERS-Detection

The best use of the duress alarm feature is ________. - ANSWERS-Sends a silentalarm when forced to disarm the alarm system

60% of home debts resulted from fires in homes with _______. - ANSWERS-Noworking smoke alarms

The four types of notifications are Audible, Visual, tactile, and _______. -ANSWERS-Olfactory

Which of these monitoring sites will most commonly be used to monitor auniversity alarm system? - ANSWERS-Proprietary supervising station One way in which signals are able to reach the appropriate monitoring site is by______. - ANSWERS-All of the above

The most common hazard to humans in a building fire is _______. - ANSWERS-Smoke inhalation

An alarm system may be controlled using _____. - ANSWERS-All of the Above A bigger gauge wire has less resistance and will carry more current, which of thecables listed and will carry the most current? - ANSWERS-6 AWG

Projected been outdoor microwave works through: - ANSWERS-Obscuration Which technology converts electrical energy to radio waves and then convertsradio waves back to electrical energy? - ANSWERS-Indoor microwave Which of the sensors is considered active? - ANSWERS-Photo beam The range of an outdoor photo beam can be as much as: - ANSWERS-660 Feet Reed switches are resistant to: - ANSWERS-Corrosion When installing outdoor photo beams in installer should: - ANSWERS-Be able toblock 85% of beam without being the cause of the alarm

Taut Wire fence detection is considered: - ANSWERS-High security Buried cable pairs have up to a ______ wide detection pattern - ANSWERS-10Feet

Alarm screens are typically: - ANSWERS-A 2 appointment installation

Dual technology motion detectors are typically: - ANSWERS-Microwave andpassive infrared technology

Which of the following is true about primary wiring to alarm system? -ANSWERS-The circuit breaker size should be 20 Amps maximum

Batteries should be attached to the panel in what configuration? - ANSWERS-Parallel

What is the type of transformer most commonly used in an alarm system? -ANSWERS-Step down

According to the NFPA, the breaker supplying power to an alarm system shallnot be: - ANSWERS-Greater than 20 Amps

What is the value for 'total Amp hours' on the previous slide? - ANSWERS-4. How long can a 12 volt, 1 Amp hour battery power an alarm system thatrequires .5 Amps total? - ANSWERS-Two hours Which of the following is recommended or required in regards to powering thefire alarm system? - ANSWERS-Dedicated circuit