Docsity
Docsity

Prepara tus exámenes
Prepara tus exámenes

Prepara tus exámenes y mejora tus resultados gracias a la gran cantidad de recursos disponibles en Docsity


Consigue puntos base para descargar
Consigue puntos base para descargar

Gana puntos ayudando a otros estudiantes o consíguelos activando un Plan Premium


Orientación Universidad
Orientación Universidad

Presentación sobre el cultivo celular, Diapositivas de Virología

como se lleva acabo el cultivo celular

Tipo: Diapositivas

2019/2020
En oferta
30 Puntos
Discount

Oferta a tiempo limitado


Subido el 13/03/2020

alejandro-brr
alejandro-brr 🇲🇽

4.3

(3)

1 documento

1 / 79

Toggle sidebar

Esta página no es visible en la vista previa

¡No te pierdas las partes importantes!

bg1
CULTIVO CELULAR
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23
pf24
pf25
pf26
pf27
pf28
pf29
pf2a
pf2b
pf2c
pf2d
pf2e
pf2f
pf30
pf31
pf32
pf33
pf34
pf35
pf36
pf37
pf38
pf39
pf3a
pf3b
pf3c
pf3d
pf3e
pf3f
pf40
pf41
pf42
pf43
pf44
pf45
pf46
pf47
pf48
pf49
pf4a
pf4b
pf4c
pf4d
pf4e
pf4f
Discount

En oferta

Vista previa parcial del texto

¡Descarga Presentación sobre el cultivo celular y más Diapositivas en PDF de Virología solo en Docsity!

CULTIVO CELULAR

Puntos Importantes

Esterilidad

Asepsia

Hábito de trabajo

  • BAÑO TERMOSTATIZADO (BAÑO MARIA)

Tanque de Nitrógeno líquido

Congelación de líneas estables

Campana de Flujo Laminar

Esterilidad!! (no evita contaminación un mal uso)

There are three types of biological safety cabinets: Class I: The Class I biological safety cabinet is an open-front negative pressure cabinet The exhaust air from the cabinet is filtered by a high-efficiency particulate air (HEPA) filter. The Class I biosafety cabinet will provide personnel and environmental protection, but not product protection. Class II: The Class II vertical laminar-flow biological cabinet is an open-front, ventilated cabinet. This cabinet provides a HEPA-filtered, recirculated mass airflow within the work space. The exhaust air from the cabinet is also filtered by HEPA filters. Thus, the Class II biosafety cabinet will provide personnel, environment and product protection. While HEPA filters are effective for trapping particulates and infectious agents, these filters will not capture volatile chemicals or gases Class III: The Class III cabinet is a totally enclosed ventilated cabinet of gas-tight construction. Operations within the Class III cabinet are conducted through attached rubber gloves. When in use, the Class III cabinet is maintained through negative air pressure of at least 0.5 inches water gauge. Supply air is drawn into the cabinet through HEPA filters. The cabinet exhaust air is filtered by two HEPA filters, installed in series, before discharge outside of the facility. The exhaust fan for the Class III cabinet is generally separate from the exhaust fans of the facility's ventilation system.

Micro Centrifuga

Suspensiones celulares (lavados, concentrados, subcultivos)